LiftMaster CSW24V CSW24V Manual - Page 30
Expansion Board Overview, Cycle Count, Quick Close Switch, Ac Fail Open/batt, Switch
View all LiftMaster CSW24V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
ADDITIONAL FEATURES EXPANSION BOARD OVERVIEW EXPANSION BOARD OVERVIEW To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks. QUICK CLOSE Switch AC FAIL OPEN/BATT Switch LOW BATT/EXIT LOOP FAIL Switch ANTI-TAIL OPEN/CLOSE SELECTION switch AUX RELAY switches OFF: No change to the gate's normal operation. ON: When CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped gate to close (ignores the Timer-to-Close). OPEN: Loss of AC power will cause gate to immediately OPEN and remain OPEN until AC power is restored (enabling the Timer-to-Close). BATT: With loss of AC power, gate will remain in present position and operator is powered from batteries. • When AC power is OFF and battery voltage is low the gate will latch at a limit until AC power is restored or batteries voltage increases. • Option select switch set to OPEN forces gate to latch at the OPEN limit if it is at the OPEN limit or on next open command until AC power is restored or battery voltage increases. • Option select switch set to CLOSE forces gate to latch at CLOSE limit if at CLOSE limit or on next CLOSE command until AC power restored or battery voltage increases. • Constant pressure on a hard command input overrides to open or close the gate. • Low battery detect point = 22 V • When set to OPEN, if the EXIT plug-in loop detector detects a fault, then the gate will open and remain open until fault is cleared. When set to CLOSE, then plug-in EXIT loop detector faults are ignored (EXIT loop is faulted and inoperative). OFF: When CLOSE EYES/Interrupt loop is activated it causes a closing gate to stop and reverse. ON: When CLOSE EYES/Interrupt loop is activated it causes a closing gate to pause. Once the vehicle is clear the gate will continue to close. Set the AUX RELAY switches as needed to obtain the desired function: AUX RELAY SWITCH SETTING SETTINGS AUX RELAY 1 123 Off (no feature OFF OFF OFF selected) Open Limit OFF OFF ON Switch Close Limit OFF ON OFF Switch Gate Motion OFF ON ON Relay always off. Use this Aux Relay setting to conserve battery power. Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier gate) Energizes when not at close limit. Connect "Gate Close/Secure" indicator (e.g. light). Energizes when motor is on (gate in motion). Connect "Gate In Motion" indicator (e.g. warning light or sounder). Pre-Motion Delay Power ON OFF OFF ON ON OFF Energizes 3 seconds before gate motion and remains energized during gate motion. Connect "Gate In Motion" indicator (e.g. warning light or sounder). Energizes when AC power or solar power is present. There is approximately a 10-12 second delay before relay cutoff, after AC shutdown. Tamper ON OFF ON Energizes if gate is manually tampered with by being pushed off of close limit. Connect alert (e.g. light or sounder). Cycle Quantity ON ON ON Feedback* The OPEN, CLOSE, and STOP LEDs will blink out the cycle count See below. CYCLE COUNT * First, note the current Aux Relay switch positions. To determine the actual cycles that the gate operator has run (in thousands), set all three Aux Relay switches to the ON setting for Aux Relay 1. The Expansion Board's OPEN, CLOSE, and STOP LEDs will blink out the cycle count, with OPEN LED blinking 1000's, CLOSE LED blink 10,000's, STOP LED blinking 100,000's, and simultaneously all three LED's blink 1,000,000's (e.g. Open blinks 3 times, Close blinks 6 times, and Stop blinks once. Cycle count is 163,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles. After servicing, set Aux Relay switches back to their appropriate positions. Cycle count cannot be reset or changed. If under 1,000 cycles the Open, Close, and Stop LEDs will turn on for 10 seconds, then turn off. SHADOW INTERRUPT EXIT F G E H 28 AUX Relay 2 N.C. Com AUX Relay 2 N.O. AUX Relay 1 N.C. Com AUX Relay 1 N.O. Exit Loop Interrupt Loop Shadow Loop AUX RELAY 2 Relay always off. Use this Aux Relay setting to conserve battery power. Energizes when at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier gate) Energizes when not at close limit. Connect "Gate Not Closed/Secure" indicator (e.g. light). Energizes when motor is on (gate in motion). Connect "Gate In Motion" indicator (e.g. warning light or sounder). Not used. Energizes when on battery power. There is approximately a 10-12 second delay before relay cutoff, after AC shutdown. Energizes if gate is manually tampered with by being pushed off of close limit. Connect alert (e.g. light or sounder). Not used. 1 Single SBC Com Open Close Stop Button D Control Station A B 3-Button Control Com C Station I