LiftMaster SL930 SL930 Manual - Page 7

Street, Complex Or, Parking Lot

Page 7 highlights

OPERATOR WARNINGS SUGGESTED ENTRAPMENT PROTECTION DEVICE LOCATIONS GATE SYSTEM (COMMERCIAL SLIDE GATE) Sentex Telephone Entry System/Access Control Open Edge Close Edge Photo Eye For Open Cycle STREET 4' Typical 8' Interrupt Loop Photo Eye For Close Cycle 4' Typical 4' Typical Interrupt Loop 4' Typical COMPLEX OR PARKING LOT Run Twisted Wire * From Loop To Detector Seal Loops * 1-1/2" Loop Wire Layer * 1/4" Or As Required For Loop Wire Width GATE SYSTEM (MASTER/SECOND SLIDE GATE) Open Edge Second Unit Open Edge STREET Photo Eye For Close Cycle Photo Eye For Open Cycle Master Unit Photo Eye For Open Cycle Close Edge Run Twisted Wire * From Loop To Detector 6' Interrupt Loop 4' Typical 4' Typical Interrupt Loop 6' 12' Typical 4' Typical COMPLEX OR PARKING LOT Seal Loops * 1-1/2" Loop Wire Layer * 1/4" Or As Required For Loop Wire Width *Refer to loop manufacturer's instructions for detailed installation and loop wiring instructions. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

7
*Refer to loop manufacturer’s instructions for detailed installation and loop wiring instructions.
GATE SYSTEM (MASTER/SECOND SLIDE GATE)
GATE SYSTEM (COMMERCIAL SLIDE GATE)
OPER AT OR WA RNINGS
SUGGESTED ENTRAPMENT PROTECTION DEVICE LOCATIONS
Sentex Telephone Entry
System/Access Control
Photo Eye For
Close Cycle
Interrupt
Loop
Interrupt
Loop
4' Typical
4' Typical
4' Typical
4' Typical
8'
STREET
COMPLEX OR
PARKING LOT
Photo Eye For
Open Cycle
Open
Edge
Close
Edge
Run Twisted Wire
*
From Loop
To Detector
Seal Loops
*
1-1/2"
Loop Wire Layer
*
1/4" Or As Required
For Loop Wire Width
STREET
COMPLEX OR
PARKING LOT
Photo Eye For
Close Cycle
Interrupt
Loop
Interrupt
Loop
4' Typical
4'
Typical
6'
Photo Eye For
Open Cycle
Open
Edge
Close
Edge
Run Twisted Wire
*
From Loop
To Detector
Seal Loops
*
1-1/2"
Loop Wire Layer
*
1/4" Or As Required
For Loop Wire Width
4'
Typical
Second Unit
Photo Eye For
Open Cycle
6'
Master Unit
Open Edge
12' Typical