MSI E7320 User Manual - Page 61

Sync Transfer Rate MB/Sec, Packetized, Initiate Wide Negotiation, Enable Disconnection

Page 61 highlights

MS-9152 ATX Server Board SCSI Device ID SCSI Device Configuration #0 #1 #2 #3 #4 #5 #6 #7 Sync Transfer Rate (MB/Sec) ........ 320 320 320 320 320 320 320 320 Packetized Yes Yes Yes Yes Yes Yes Yes Yes QAS Yes Yes Yes Yes Yes Yes Yes Yes Initiate Wide Negotiation Yes Yes Yes Yes Yes Yes Yes Yes Enable Disconnection Yes Yes Yes Yes Yes Yes Yes Yes Send Start Unit Command Yes Yes Yes Yes Yes Yes Yes Yes BIOS Multiple LUN Support ......... No No No No No No No No Include in BIOS Scan Yes Yes Yes Yes Yes Yes Yes Yes SCSI Device ID #8 #9 #10 #11 #12 #13 #14 #15 Sync Transfer Rate (MB/Sec) ........ 320 320 320 320 320 320 320 320 Packetized Yes Yes Yes Yes Yes Yes Yes Yes QAS Yes Yes Yes Yes Yes Yes Yes Yes Initiate Wide Negotiation Yes Yes Yes Yes Yes Yes Yes Yes Enable Disconnection Yes Yes Yes Yes Yes Yes Yes Yes Send Start Unit Command Yes Yes Yes Yes Yes Yes Yes Yes BIOS Multiple LUN Support ......... No No No No No No No No Include in BIOS Scan Yes Yes Yes Yes Yes Yes Yes Yes Sync Transfer Rate (MB/Sec) The field allows you to specify the maximum synchronous data transfer rate depending on the type of each SCSI device. Select [ASYN] to enable asynchronous negotiation for some older SCSI devices. Packetized When enabled, this option is supported by the device drivers. However, this option is not supported by the BIOS. QAS When enabled, this option is supported by the device drivers. However, this option is not supported by the BIOS. Initiate Wide Negotiation When set to Yes, the field allows wide SCSI hard drives to use 16-bit (2 bytes) transfers. Enable Disconnection This field tells the SCSI controller whether or not to allow the specified SCSI device to disconnect during an I/O transfer operation. The disconnection ability frees the SCSI bus to allow other I/O processes and thus optimizes the SCSI bus performance. Setting options: [Yes], [No]. A-6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

A-6
MS-9152 ATX Server Board
Sync Transfer Rate (MB/Sec)
The field allows you to specify the maximum synchronous data transfer rate
depending on the type of each SCSI device.
Select [ASYN] to enable asynchro-
nous negotiation for some older SCSI devices.
Packetized
When enabled, this option is supported by the device drivers.
However, this
option is not supported by the BIOS.
QAS
When enabled, this option is supported by the device drivers.
However, this
option is not supported by the BIOS.
Initiate Wide Negotiation
When set to
Yes
, the field allows wide SCSI hard drives to use 16-bit (2 bytes)
transfers.
Enable Disconnection
This field tells the SCSI controller whether or not to allow the specified
SCSI
device to disconnect during an I/O transfer operation.
The disconnection ability
frees the SCSI bus to allow other I/O processes and thus optimizes the SCSI
bus performance. Setting options: [Yes], [No].
SCSI Device ID
#0
#1
#2
#3
#4
#5
#6
#7
Sync Transfer Rate (MB/Sec)
........
320
320
320
320
320
320
320
320
Packetized
.........................................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
QAS
...................................................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Initiate Wide Negotiation
..............
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Enable Disconnection
.....................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Send Start Unit Command
.............
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
BIOS Multiple LUN Support
.........
No
No
No
No
No
No
No
No
Include in BIOS Scan
......................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SCSI Device ID
#8
#9
#10
#11
#12
#13
#14
#15
Sync Transfer Rate (MB/Sec)
........
320
320
320
320
320
320
320
320
Packetized
.........................................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
QAS
...................................................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Initiate Wide Negotiation
..............
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Enable Disconnection
.....................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Send Start Unit Command
.............
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
BIOS Multiple LUN Support
.........
No
No
No
No
No
No
No
No
Include in BIOS Scan
......................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SCSI Device Configuration