Maytag MFI2266AES Service Manual - Page 55

Water Filter - canada

Page 55 highlights

Water Filter Water Filter Removal and Installation WARNING To avoid serious illness or death, do not use refrigerator where water is unsafe or of unknown quality without adequate disinfection before or after use of filter. CAUTION After installing a new water filter, always dispense water for two minutes before removing the filter for any reason. Air trapped in system may cause water and cartridge to eject. Use caution when removing. • The bypass cap does not filter water. Be sure to have replacement cartridge available when filter change is required. • If water filtration system has been allowed to freeze, replace filter cartridge. • If system has not been used for several months, or water has an unpleasant taste or odor, flush system by dispensing water for two to three minutes. If unpleasant taste or odor persists, change filter cartridge. Initial Installation The water filter is located in the upper right-hand corner of the fresh food compartment. 1. Remove blue bypass cap and retain for later use. 2. Remove sealing label from end of filter and insert into filter head. 3. Rotate gently clockwise until filter stops. Snap filter cover closed. Pull tab to remove Replacing Water Filter Important: Air trapped in system may cause water and cartridge to eject. Always dispense water for at least 2 minutes before removing the filter for any reason. Use caution when removing. 1. Turn filter counterclockwise until it releases from filter head. 2. Drain water from filter into sink, and dispose in normal household trash. 3. Wipe up excess water in filter cover and continue with Initial Installation, steps 2 through 3. The filter should be changed at least every 12 months. Important: Condition of water and amount used determines life span of water filter cartridge. If water use is high, or if water is of poor quality, replacement may need to take place more often. To purchase a replacement water filter cartridge, contact your dealer or call 1-877-232-6771 USA or 1-800-688-8408 Canada. The dispenser feature may be used without a water filter cartridge. If you choose this option, replace filter with blue bypass cap. State of California Department of Health Services Water Treatment Device Certificate Number 03 - 1583 Date Issued: September 16, 2003 Date Revised: April 22, 2004 Trademark /Model Designation Replacement Elements UKF8001AXX750 UKF8001AXX 469006-750 46 9006 67003523-750 Manufacturer: PentaPure Inc. 67003523 The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminant's: Microbiological contaminant's and Turbidity Cysts Turbidity Inorganic/Radiological contaminant's Asbestos Lead Mercury Organic contaminant's Atrazine Lindane Benzene Carbofuran p-dichlorobenzene Toxaphene Rated Service Capacity: 750 gal. Rated Service Flow: 0.78 gpm Conditions of Certification: Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

14
Water Filter
Water Filter Removal
and Installation
To avoid serious illness or death,
do not
use
refrigerator where water is unsafe or of unknown
quality without adequate disinfection before or after
use of filter.
WARNING
After installing a new water filter, always
dispense water for two minutes
before
removing the filter for any reason. Air trapped in
system may cause water and cartridge to eject.
Use caution when removing.
The bypass cap does not filter water. Be sure to
have replacement cartridge available when filter
change is required.
If water filtration system has been allowed to
freeze, replace filter cartridge.
If system has not been used for several months, or
water has an unpleasant taste or odor, flush
system by dispensing water for two to three
minutes. If unpleasant taste or odor persists,
change filter cartridge.
CAUTION
Initial Installation
The water filter is
located in the upper
right-hand corner of the
fresh food
compartment.
1. Remove blue bypass
cap and retain for
later use.
2. Remove sealing
label from end of
filter and insert into
filter head.
3. Rotate gently
clockwise
until filter
stops. Snap filter
cover closed.
Replacing Water Filter
Important:
Air trapped in system may cause
water and cartridge to eject. Always dispense
water for at least 2 minutes
before
removing the
filter for any reason. Use caution when removing.
1. Turn filter
counterclockwise
until it releases from
filter head.
2. Drain water from filter into sink, and dispose in
normal household trash.
3. Wipe up excess water in filter cover and continue
with
Initial Installation
, steps 2 through 3.
The filter should be changed at least every 12 months.
Important:
Condition of water and amount used
determines life span of water filter cartridge. If water
use is high, or if water is of poor quality, replacement
may need to take place more often.
To purchase a replacement water filter cartridge,
contact your dealer or call 1-877-232-6771 USA or
1-800-688-8408 Canada.
The dispenser feature may be used without a water
filter cartridge. If you choose this option, replace filter
with blue bypass cap.
State of California
Department of Health Services
Water Treatment Device
Certificate Number
03 - 1583
Date Issued:
September 16, 2003
Date Revised: April 22, 2004
T
rademar
k
/Model Designation
Replacement Elements
UKF8001AXX750
UKF8001AXX
469006-750
46 9006
67003523-750
67003523
Manufacturer:
PentaPure Inc.
The water treatment device(s) listed on this certificate have met the testing requirements
pursuant to Section 116830 of the Health and Safety Code for the following health related
contaminant's:
Micr
obiological contaminant's and
T
urbidity
Inorganic/Radiological contaminant's
Cysts
Asbestos
Turbidity
Lead
Mercury
Organic contaminant's
Atrazine
Lindane
Benzene
Carbofuran
p-dichlorobenzene
Toxaphene
Rated Service Capacity:
750 gal.
Rated Service Flow:
0.78 gpm
Conditions of Certification:
Do not
use where water is microbiologically unsafe or with water of unknown quality, except that
systems certified for cyst reduction may be used on disinfected waters that may contain filterable
cysts.
Pull tab to remove