Onkyo TX-RZ70 TX RZ Manual - En - Page 167
results and register them in 3 slots, register can be selected with Room EQ - Dirac Live
View all Onkyo TX-RZ70 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
7. The guidance about outputting the test tone is displayed. Refer to the illustration to set up the speaker setup microphone in the listening position. Follow the on-screen instructions to measure. • Measurement may not be possible if the test tone is too loud or too soft. Tap "Level Adjust" to adjust the volume of the test tone. 8. When measurement is complete, "Calculating results" is displayed on the screen. Tap "Transfer to your product" to transfer the measurement data to the unit. 9. Disconnect the speaker setup microphone. The speaker adjustments based on the measurement results are saved in the unit. You can modify 3 patterns of the filter curves from the measurement results and register them in 3 slots ( →p172). The filter curves that you register can be selected with "Room EQ" - "Dirac Live" ( →p93) in "Quick Menu". • When Dirac Live is used for measurement, the measurement results are also reflected in "Speaker" - "Distance" ( →p137) in the Setup menu, and you will no longer be able to change the values. (The setting units are displayed as "msec".) Setup 167