Panasonic PT-EZ570U Operating Instructions - Page 102

When WEB Control administrator rights password is not set Non-protect, Connection method

Page 102 highlights

Technical Information JJWhen WEB Control administrator rights password is not set (Non-protect mode) zzConnection method 1111 Obtain the IP address and port number (Initial set value = 1 024) of the projector and make a request for connection to the projector. Acquire the IP address from the menu screen of the projector, and the port number from the WEB control page. IP address : Obtain from MAIN MENU → [Network] → [Network status] Port No. : Acquire from the WEB control "Detailed set up" → "Command port set up" page 2222 There is a response from the projector. Response data Data section "NTCONTROL" (ASCII string) Blank ' ' 0x20 Mode '0' 0x30 Termination symbol (CR) 0x0d 9 bytes 1 byte 1 byte 1 byte Mode : 0 = Non-protect mode zzCommand transmission method Transmit by the following command format. Transmitted data '0' 0x30 1 byte Header '0' 0x30 1 byte Data section Control command (ASCII string) Undefined length Termination symbol (CR) 0x0d 1 byte Receive data '0' 0x30 1 byte Header '0' 0x30 1 byte Data section Control command (ASCII string) Undefined length Termination symbol (CR) 0x0d 1 byte Receive data "ERR1" "ERR2" "ERR3" "ERR4" "ERR5" "ERRA" Error message Undefined control command Out of parameter range Busy state or no-acceptable period Timeout or no-acceptable period Wrong data length Password mismatch 4 bytes Termination symbol (CR) 0x0d 1 byte Appendix 102 - ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

Technical Information
102
- ENGLISH
Appendix
When WEB Control administrator rights password is not set (Non-protect
J
mode)
Connection method
z
Obtain the IP address and port number (Initial set value = 1 024) of the projector and
1 )
make a request for connection to the projector.
Acquire the IP address from the menu screen of the projector, and the port number from the WEB control
page.
IP address :
Obtain from MAIN MENU → [Network] → [Network status]
Port No. :
Acquire from the WEB control “Detailed set up” → “Command port set up” page
There is a response from the projector.
2 )
Response data
Data section
Blank
Mode
Termination symbol
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘0’
0x30
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
Mode : 0 = Non-protect mode
Command transmission method
z
Transmit by the following command format.
Transmitted data
Header
Data section
Termination symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
Receive data
Header
Data section
Termination symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
Receive data
Error message
Termination symbol
“ERR1”
“ERR2”
“ERR3”
“ERR4”
“ERR5”
“ERRA”
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
(CR)
0x0d
4 bytes
1 byte