Pentax SF-1 SF-1 Manual - Page 67
frame
View all Pentax SF-1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Self-timer: Electronically-controlled type. 12-sec. delay time. Start by shutter release button. Operation confirmation by LED indicator, PCV sound and CENTIC panel. Cancellation by exposure-mode-clear button or main switch off. Mirror: Swing-up-type instant-return mirror with AF secondary mirror. Film advance/ rewind: Auto wind /rewind and auto rewind stop by built-in wind motor. Consecutive or single advance mode. Approx. 1.8-frame-per-second advance speed. Exposure control: TTL center-weighted, averaged-area metering by GPD cell. Metering range from EV 1 to EV 20 at ISO 100 with 50mm f/1.4 lens. Exposure compensation: EV -4 to EV 4 in 1/2 steps. Exposurememory lock: Built-in flash: By exposure-memory-lock (ML) button. Parallel-controlled retractable TTL Auto Flash (RTF) with AF Spotbeam Projector. Guide number: 14 (ISO 100 in meters). Covers angle of view for 35mm wide-angle lens. Flash sync: Power source: Low battery warning: Via hot shoe with X-contact which couples with Pentax dedicated auto flashes. One 6V lithium battery pack for standard Lithium Battery Grip, or four 1.5V AA-size alkaline batteries for optional AA-size Battery Grip. By blinking battery warning mark in CENTIC panel and blinking viewfinder LED under standard voltage supply. Back cover: Dimensions/ weight: Standard accessories: Interchangeable for accepting Data Back F or Interval Data Back F. 157(W) x 99(H) x 63.5(D)mm (6.1 x 3.9 x 2.5 in.). 665 grams (23.3 oz) without batteries. Hot-shoe cover, Release-socket cap F, Eyecup F, Body-mount cover F, and Camera strap F. 63*