Command GS v 0 m xL xH yL yH d1...dk [Name] Print raster bit image. [Format] ASCII GS V 0 m xL xH yL yH d1...dk Hex 1D 76 30 m xL xH yL yH d1...dk Decimal 29 118 48 m xL xH yL yH d1...dk [Range] 0 ≤m ≤3, 48 ≤m ≤51 0 ≤xL ≤255 0 ≤xH ≤255 0 ≤yL ≤255 0 ≤d ≤255 k = (xL + xH ×256) ×(yL + yH ×256) (k ≠0) [Description] Selects Raster bit-image mode. The value of m selects the mode, as follows : m 0, 48 1, 49 2, 50 3, 51 Mode Vertical Dot Density (DIP) Horizontal Dot Density (DIP) Normal 180 DPI 180 DPI Double-width 180 DPI 90 DPI Double-height 90 DPI 180 DPI Quadruple 90 DPI 90 DPI * xL, xH, select the number of data bits (xL + xH ×256) in the horizontal direction for the bit image. * yL, yH, select the number of data bits (yL + yH ×256) in the vertical direction for the bit image. GS w n [Name] [Format] [Range] [Description] Set bar code width. ASCII GS w n Hex 1D 77 n Decimal 29 119 n 2 ≤n ≤6 Set the horizontal size of the bar code. n specifies the bar code width as follows : Module width for n multi-level bar code Thin element width (mm) Binary-level bar code Thick element width (mm) 2 0.282 0.282 0.706 3 0.423 0.423 1.129 4 0.564 0.564 1.411 5 0.706 0.706 1.834 6 0.847 0.847 2.258 * Multi-level bar codes are as follows : UPC-A, UPC-E, JAN13(EAN13), JAN8(EAN8), CODE93, CODE128. * Binary-level bar codes are as follows : CODE39, ITF, CODABAR. 8-18 Samsung Electro-Mechanics