Sharp PN-C703B Pen Software Operation Manual - Page 49

Controlling the Monitor with a PC RS-232C, Initialization/Functional Restriction Setting FUNCTION

Page 49 highlights

Controlling the Monitor with a PC (RS-232C) Initialization/Functional Restriction Setting (FUNCTION) menu Function ALL RESET ADJUSTMENT LOCK ADJUSTMENT LOCK TARGET OSD DISPLAY LED TEMPERATURE ALERT STATUS ALERT POWER BUTTON EXTERNAL CONTROLLER INPUT Command Direction RSET W ALCK WR ALTG WR LOSD WR OFLD WR TALT WR SALT WR PBTN WR PCIP WR Parameter 0-1 0-2 0-2 0-2 0-1 0-2 0-2 0-1 0-5 Reply Control/Response contents * 0: ALL RESET 1, 1: ALL RESET 2 - 0-2 0: OFF, 1:ON1, 2:ON2 When STANDBY MODE is set to LOW POWER, ON2 cannot be selected (ERR). 0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH "ERR" when OFF is selected for ADJUSTMENT LOCK. 0-2 0: ON1, 1: OFF, 2: ON2 0-1 0: ON, 1: OFF ○ 0-2 0: OFF, 1: OSD & LED, 2: LED 0-2 0: OFF, 1: OSD & LED, 2: LED 0-1 0: MONITOR, 1: EXT. CONTROLLER 0-5 0: D-SUB1, 1: D-SUB2, 2: DisplayPort, 3: HDMI1, 4: HDMI2, 5: HDMI3 "ERR" when MONITOR is selected for POWER BUTTON. Others Function SCREEN SIZE (PC) SCREEN SIZE (AV) VOLUME MUTE INFORMATION MODEL SERIAL NO TEMPERATURE SENSOR Command Direction WIDE WR WIDE WR VOLM WR MUTE WR INF1 R SRNO R DSTA R Parameter 0-5 0-5 0-31 0-1 Temperature acquisition ERRT R CAUSE OF LAST STANDBY MODE STCA W 0 R Touch operation valid/invalid TPEN WR 0-1 Reply Control/Response contents * 0-5 0: Toggle to change size, 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2 0-5 0: Toggle to change size, 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot ○ 0-31 0-1 0: OFF, 1: ON - Value Value 0 Internal temperature normal 1 Internal temperature abnormal has occurred and the monitor is in standby mode 2 Internal temperature abnormal occurred (To delete the information of temperature abnormal, turn off the main power.) 3 Internal temperature abnormal has occurred and backlight brightness is dimmed 4 Temperature sensor abnormal Value Returns the temperature at the temperature sensors. Indicates a temperature sensor abnormality when "126" is returned. ○ Initialization 0 No detectable error has occurred 1 Standby mode by POWER button 2 Main power off by the main power switch 3 Standby mode by RS-232C or LAN 4 Input signal waiting mode by No Signal 6 Standby mode by abnormal temperature 8 Standby mode by SCHEDULE setting 20 Standby mode by OFF IF NO OPERATION setting 0-1 0: Invalid, 1: Valid "ERR" when TOUCH INPUT SELECT is set to INVALID or the touch panel is not connected. 49 E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

49
E
Controlling the Monitor with a PC (RS-232C)
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
ALL RESET
RSET
W
0-1
0: ALL RESET 1, 1: ALL RESET 2
-
ADJUSTMENT LOCK
ALCK
WR
0-2
0-2
0: OFF, 1:ON1, 2:ON2
When STANDBY MODE is set to LOW POWER, ON2 cannot be selected (ERR).
ADJUSTMENT LOCK TARGET
ALTG
WR
0-2
0-2
0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH
“ERR” when OFF is selected for ADJUSTMENT LOCK.
OSD DISPLAY
LOSD
WR
0-2
0-2
0: ON1, 1: OFF, 2: ON2
LED
OFLD
WR
0-1
0-1
0: ON, 1: OFF
TEMPERATURE ALERT
TALT
WR
0-2
0-2
0: OFF, 1: OSD & LED, 2: LED
STATUS ALERT
SALT
WR
0-2
0-2
0: OFF, 1: OSD & LED, 2: LED
POWER BUTTON
PBTN
WR
0-1
0-1
0: MONITOR, 1: EXT. CONTROLLER
EXTERNAL CONTROLLER INPUT
PCIP
WR
0-5
0-5
0: D-SUB1, 1: D-SUB2, 2: DisplayPort, 3: HDMI1, 4: HDMI2, 5: HDMI3
“ERR” when MONITOR is selected for POWER BUTTON.
Others
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
SCREEN SIZE (PC)
WIDE
WR
0-5
0-5
0: Toggle to change size, 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
SCREEN SIZE (AV)
WIDE
WR
0-5
0-5
0: Toggle to change size, 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
VOLUME
VOLM
WR
0-31
0-31
MUTE
MUTE
WR
0-1
0-1
0: OFF, 1: ON
-
INFORMATION
MODEL
INF1
R
Value
SERIAL NO
SRNO
R
Value
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
1
Internal temperature abnormal has occurred and the monitor is in standby mode
2
Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3
Internal temperature abnormal has occurred and backlight brightness is dimmed
4
Temperature sensor abnormal
TEMPERATURE ACQUISITION
ERRT
R
Value
Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
R
0
No detectable error has occurred
1
Standby mode by POWER button
2
Main power off by the main power switch
3
Standby mode by RS-232C or LAN
4
Input signal waiting mode by No Signal
6
Standby mode by abnormal temperature
8
Standby mode by SCHEDULE setting
20
Standby mode by OFF IF NO OPERATION setting
Touch operation valid/invalid
TPEN
WR
0-1
0-1
0: Invalid, 1: Valid
“ERR” when TOUCH INPUT SELECT is set to INVALID or the touch panel is not
connected.
-