Sharp PN-C703B Pen Software Operation Manual - Page 50
Controlling the Monitor with a PC RS-232C, Commands for setting of the GAMMA user data
View all Sharp PN-C703B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Controlling the Monitor with a PC (RS-232C) Commands for setting of the GAMMA user data Function Command Direction Parameter Reply Control/Response contents * RED GAMMA DATA TRANSFER UGRW W aaxxxx ··· xxxxcc aa: Block number GREEN GAMMA DATA TRANSFER BLUE GAMMA DATA TRANSFER UGGW W UGBW W (xxxx: 32 pieces) aa: 01-16 xxxx: 0000-1023 xxxx: 32 pieces of user data cc: Checksum (ASCII data) of the block number and user data cc: 00-FF RED GAMMA DATA READ UGRR W 1-16 xxxx ··· xxxx xxxx: User data of 32 pieces ○ GREEN GAMMA DATA READ BLUE GAMMA DATA READ UGGR W UGBR W 1-16 (xxxx: 32 pieces) 1-16 xxxx: 0000-1023 USER DATA INITIALIZE UGRS W 0 Initialize the user data. USER DATA SAVE UGSV W 0 Save the user data in the monitor. E 50
50
E
Controlling the Monitor with a PC (RS-232C)
Commands for setting of the GAMMA user data
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
RED GAMMA DATA TRANSFER
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
○
GREEN GAMMA DATA TRANSFER
UGGW
W
BLUE GAMMA DATA TRANSFER
UGBW
W
RED GAMMA DATA READ
UGRR
W
1-16
xxxx ··· xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
GREEN GAMMA DATA READ
UGGR
W
1-16
BLUE GAMMA DATA READ
UGBR
W
1-16
USER DATA INITIALIZE
UGRS
W
0
Initialize the user data.
USER DATA SAVE
UGSV
W
0
Save the user data in the monitor.