Sony EVIHD7V Product Manual (HD Color Video Camera) - Page 25
VISCA Camera-Issued Messages, ACK/Completion Messages, Error Messages, Network Change Message
View all Sony EVIHD7V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
VISCA Camera-Issued Messages ACK/Completion Messages Command List ACK Completion z = Device address + 8 Command Messages z0 4y FF (y:Socket No.) z0 5y FF (y:Socket No.) Comments Returned when the command is accepted. Returned when the command has been executed. Error Messages Syntax Error Command Buffer Full Command Canceled No Socket Command Not Executable Command Messages Comments z0 60 02 FF Returned when the command format is different or when a command with illegal command parameters is accepted. z0 60 03 FF Indicates that two sockets are already being used (executing two commands) and the command could not be accepted when received. z0 6y 04 FF (y:Socket No.) Returned when a command which is being executed in a socket specified by the cancel command is canceled. The completion message for the command is not returned. z0 6y 05 FF (y:Socket No.) Returned when no command is executed in a socket specified by the cancel command, or when an invalid socket number is specified. z0 6y 41 FF Returned when a command cannot be executed due to current conditions. For (y:Execution command example, when commands controlling the focus manually are received during auto Socket No. Inquiry command:0) focus. z = Device address + 8 Network Change Message Network Change z = Device address + 8 Command Message z0 38 FF Comments Issued when power is being routed to the camera, or when the VISCA device is connected to or disconnected from the VISCA OUT connector. 25