Sony VPL-VW85 Operating Instructions - Page 65

Warning Indicators, The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any

Page 65 highlights

Others Warning Indicators The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any trouble with your projector. LAMP/COVER indicator ON/STANDBY indicator Symptom LAMP/COVER flashes in red. (A repetition rate of 2 flashes) LAMP/COVER flashes in red. (A repetition rate of 3 flashes) ON/STANDBY flashes in red. (A repetition rate of 4 flashes) ON/STANDBY flashes in red. (A repetition rate of 2 flashes) Cause and Remedy c Close the lamp cover securely, then tighten the screws securely. (1 page 69) c Close the filter holder securely. (1 page 70) c The lamp has reached the end of its useful lifespan. Replace the lamp. (1 page 68) c The lamp has reached a high temperature. Wait until the lamp cools, and then turn on the power again. c The fan is broken. Consult with qualified Sony personnel. c The internal temperature is unusually high. Check to ensure that if nothing is blocking the ventilation holes or whether or not the projector is being used at high altitudes. ON/STANDBY flashes in red. (A repetition rate of 6 flashes) c Press the ?/1 (ON/STANDBY) switch to turn on the projector. If the power is not turned on, disconnect the AC power cord, then confirm the ON/STANDBY lamp is turned off. After about 10 seconds, reconnect the AC power cord and turn on the power again. If the indicators still light up, the electrical system has a problem. Consult with qualified Sony personnel. 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

65
Others
The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any
trouble with your projector.
Warning Indicators
Symptom
Cause and Remedy
LAMP/COVER flashes in
red. (A repetition rate of 2
flashes)
c
Close the lamp cover securely, then tighten the screws securely.
(
1
page 69)
c
Close the filter holder securely. (
1
page 70)
LAMP/COVER flashes in
red. (A repetition rate of 3
flashes)
c
The lamp has reached the end of its useful lifespan. Replace the
lamp. (
1
page 68)
c
The lamp has reached a high temperature. Wait until the lamp
cools, and then turn on the power again.
ON/STANDBY flashes in
red. (A repetition rate of 4
flashes)
c
The fan is broken. Consult with qualified Sony personnel.
ON/STANDBY flashes in
red. (A repetition rate of 2
flashes)
c
The internal temperature is unusually high. Check to ensure that
if nothing is blocking the ventilation holes or whether or not the
projector is being used at high altitudes.
ON/STANDBY flashes in
red. (A repetition rate of 6
flashes)
c
Press the
?
/
1
(ON/STANDBY) switch to turn on the projector. If
the power is not turned on, disconnect the AC power cord, then
confirm the ON/STANDBY lamp is turned off. After about 10
seconds, reconnect the AC power cord and turn on the power
again. If the indicators still light up, the electrical system has a
problem. Consult with qualified Sony personnel.
ON/STANDBY indicator