Stihl MS 441 C-M MAGNUM174 Product Instruction Manual - Page 54

of operation

Page 54 highlights

English The following information applies in normal operating conditions. The specified intervals must be shortened accordingly when working for longer than normal or under difficult cutting conditions (extensive dust, highly resinous lumber, lumber from tropical trees, etc.). If the machine is only used occasionally, the intervals can be extended accordingly. Before starting work At the end of work and/or daily Whenever tank is refilled Weekly Monthly Yearly If faulty If damaged As required Air filter Clean Replace X X X Anti-vibration elements Check X Have them replaced by a servicing dealer1) X X Air intake on fan housing Clean X X X Cylinder fins Clean X X X Check idle adjustment - saw chain must not rotate X X Carburetor If the saw chain rotates in idle, have the chain saw serviced by a servicing X dealer1) Spark plug Accessible screws, nuts and bolts Spark arresting screen in muffler Adjust electrode gap Replace after 100 hours of operation Tighten2) Have checked by a specialist dealer1) Have cleaned by a specialist dealer, or replaced if necessary1) X X X X X Check X Chain catcher Replace X Decarbonise after 139 hours of opera- Exhaust bore tion, subsequently after every 150 hours X of operation Safety information label Replace X 1) STIHL recommends STIHL servicing dealers 2) During initial use of chain saws (with a power output of 3.4 kW or more), tighten the cylinder block screws after 10 to 20 hours of operation 52 MS 441 C-M

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

MS 441 C-M
English
52
Air filter
Clean
X
X
Replace
X
Anti-vibration elements
Check
X
X
Have them replaced by a servicing
dealer
1)
X
Air intake on fan housing
Clean
X
X
X
Cylinder fins
Clean
X
X
X
Carburetor
Check idle adjustment – saw chain must
not rotate
X
X
If the saw chain rotates in idle, have the
chain saw serviced by a servicing
dealer
1)
X
Spark plug
Adjust electrode gap
X
Replace after 100 hours of operation
X
Accessible screws, nuts and bolts
Tighten
2)
X
Spark arresting screen in muffler
Have checked by a specialist dealer
1)
X
Have cleaned by a specialist dealer, or
replaced if necessary
1)
X
Chain catcher
Check
X
Replace
X
Exhaust bore
Decarbonise after 139 hours of opera
-
tion, subsequently after every 150 hours
of operation
X
Safety information label
Replace
X
1)
STIHL recommends STIHL servicing dealers
2)
During initial use of chain saws (with a power output of 3.4 kW or more), tighten the cylinder block screws after 10 to 20 hours of operation
The following information applies in normal operating conditions. The specified inter
-
vals must be shortened accordingly when working for longer than normal or under
difficult cutting conditions (extensive dust, highly resinous lumber, lumber from trop
-
ical trees, etc.). If the machine is only used occasionally, the intervals can be
extended accordingly.
Before starting work
At the end of work and/or
daily
Whenever tank is refilled
Weekly
Monthly
Yearly
If faulty
If damaged
As required