4 - Operation Auto Revert Choices: With AUTO REVERT - WRITE/TRIM enabled, the automation system stops recording switch events automatically on a per control basis, without any need to end writing manually. In this case, keys stop recording switch events at different times, depending on when they were last pressed and depending on the value set in CONTROL SENSE TIMEOUT. In the case of control surface keys, writing ends when the CONTROL SENSE TIMEOUT has expired without a key press. CONTROL SENSE TIMEOUT allows the control surface keys to respond as if they are touch-sensitive, even though they are not. Writing switch events over a Static switch position simply adds the new switch events. When writing new switch events over previous ones, the DM-24 automation system provides you with a high degree of flexibility over when writing will end. See the diagram below to understand this behavior: Existing Switch Events 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec +12 Switch ON Switch ON +6 +3 0 -3 Switch OFF Switch OFF -6 -12 New Switch Events 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec +12 Switch ON +6 +3 0 -3 Switch OFF -6 -9 -12 Control Sense Timeout Resulting Switch Events 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec +12 Switch ON +6 +3 0 -3 Switch OFF -6 -9 -12 Control Sense Timeout Figure 17 - Writing new switch events over previous switch events with Auto Revert enabled. 24 TASCAM DM-24 Automation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

4 – Operation
24
TASCAM DM-24 Automation
Auto Revert Choices:
With
AUTO REVERT
WRITE/TRIM
enabled, the auto-
mation system stops recording switch events auto-
matically on a per control basis, without any need to
end writing manually. In this case, keys stop record-
ing switch events at different times, depending on
when they were last pressed and depending on the
value set in
CONTROL SENSE TIMEOUT
.
In the case of control surface keys, writing ends
when the
CONTROL SENSE TIMEOUT
has expired with-
out a key press.
CONTROL SENSE TIMEOUT
allows the
control surface keys to respond as if they are
touch-sensitive, even though they are not.
Writing switch events over a Static switch position
simply adds the new switch events. When writing
new switch events over previous ones, the DM-24
automation system provides you with a high degree
of flexibility over when writing will end.
See the diagram below to understand this behavior:
Figure 17 – Writing new switch events over previous switch events with Auto Revert enabled.
8 sec
8 sec
8 sec
Control
Sense
Timeout
Control
Sense
Timeout
+12
+6
+3
0
-3
-6
-12
+12
+6
+3
0
-3
-6
-12
1 sec
2 sec
3 sec
4 sec
5 sec
6 sec
7 sec
1 sec
2 sec
3 sec
4 sec
5 sec
6 sec
7 sec
-9
+12
+6
+3
0
-3
-6
-12
1 sec
2 sec
3 sec
4 sec
5 sec
6 sec
7 sec
-9
Existing Switch Events
New Switch Events
Resulting Switch Events
Switch ON
Switch ON
Switch ON
Switch ON
Switch OFF
Switch OFF
Switch OFF
Switch OFF