TASCAM DM-24 Installation and Use Automation Manual - Page 25
neously when
View all TASCAM DM-24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
4 - Operation Disabling Auto Revert allows you to stop writing switch events manually, either by stopping the time code or by pressing the REVERT key. In this case, all controls that are writing will stop writing simulta- neously when REVERT is pressed or when time code stops. See the diagram below to understand this behavior: Existing Switch Events 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec +12 Switch ON Switch ON Switch ON +6 +3 0 -3 Switch OFF Switch OFF -6 -12 New Switch Events 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec +12 +6 +3 0 -3 Switch OFF -6 -9 -12 Resulting Switch Events Press REVERT 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec +12 Switch ON Switch ON +6 +3 0 -3 Switch OFF -6 -9 -12 Figure 18 - Writing new switch events over previous switch events with Auto Revert disabled. TASCAM DM-24 Automation 25