TP-Link T1600G-52PS TL-SG2452P T1600G-28PSTL-SG2424P V1 User Guide - Page 240
Alarm Config
View all TP-Link T1600G-52PS TL-SG2452P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 240 highlights
14.3.4 Alarm Config On this page, you can configure Statistic Group and Alarm Group for RMON. Choose the menu SNMP→RMON→Alarm to load the following page. Figure 13-12 Alarm Config The following entries are displayed on this screen: Alarm Config Select: Select the desired entry for configuration. Index: Displays the index number of the entry. Variable: Select the alarm variables from the pull-down list. Statistics: Select the RMON statistics entry from which we get the value of the selected alarm variable. Sample Type: Specify the sampling method for the selected variable and comparing the value against the thresholds. Absolute: Compares the values directly with the thresholds at the end of the sampling interval. Delta: Subtracts the last sampled value from the current value. The difference in the values is compared to the threshold. Rising Threshold: Enter the rising counter value that triggers the Rising Threshold alarm. Rising Event: Select the index of the corresponding event which will be triggered if the sampled value is larger than the Rising Threshold. Falling Threshold: Enter the falling counter value that triggers the Falling Threshold alarm. Falling Event: Select the index of the corresponding event which will be triggered if the sampled value is lower than the Falling Threshold. 230