TRENDnet TE100-P1U User Guide - Page 36

Port Tab, Physical Port, Logical Port, Selected Physical Port, Handshake Signal, Printer Type - reset

Page 36 highlights

Port Tab This screen has 2 panels - Physical Port and Logical Port. Physical Port The following settings are available: • Selected Physical Port - Select the Physical Printer Port you wish to configure. • Handshake Signal - Select Busy Only or Busy & Ack for the Physical Port. • Printer Type - Select High Speed or Low Speed for the Printer Type. Logical Port Logical Ports (printers) can be used in the Unix environment. The following settings are available: • Selected Logical Port - Select the Logical Printer Port you wish to configure. • Map to Physical Port - Select the physical Printer Port which the Logical printer will use. • Convert LF to LF+CR - If checked, LF (line feed) characters are changed to CR+LF (carriage return + line feed). • Prefix of Job - The printer control string (in hex) to be sent to the printer before each print job. This string cannot exceed 15 characters. • Suffix of Job - The printer control string (in hex) to be sent to the printer after each print job. This string cannot exceed 15 characters. Figure 28: Port Screen The Get Defaults button will reset all settings to their factory-default values. Page 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Port Tab
This screen has 2 panels -
Physical Port
and
Logical Port
.
Physical Port
The following settings are available:
Selected Physical Port
- Select the Physical Printer Port you wish to configure.
Handshake Signal
- Select
Busy Only
or
Busy & Ack
for the Physical Port.
Printer Type -
Select
High Speed
or
Low Speed
for the Printer Type.
Logical Port
Logical Ports (printers) can be used in the Unix environment. The following settings are
available:
Selected Logical Port
- Select the Logical Printer Port you wish to configure.
Map to Physical Port
- Select the physical Printer Port which the Logical printer will use.
Convert LF to LF+CR
- If checked, LF (line feed) characters are changed to CR+LF
(carriage return + line feed).
Prefix of Job
- The printer control string (
in hex
) to be sent to the printer before each print
job. This string cannot exceed 15 characters.
Suffix of Job
- The printer control string (
in hex
) to be sent to the printer after each print
job. This string cannot exceed 15 characters.
Figure 28: Port Screen
The
Get Defaults
button will reset all settings to their factory-default values.
Page 33