| THERMADOR | VENTILATION | THERMADOR | VENTILATION INSTALLATION Downdraft Flexible Blower Installation - Side Exhaust with Slim 2' Rectangular Duct Example Application - Side exhaust option to preserve precious kitchen storage space or if ducting is more convenient for this configuration* - A slim 2' rectangular duct is available to place flexible blower in areas such as unused corner in island or peninsula applications - Blower must be accessible for maintenance - Elbow and duct work are not included Required Blower Required Accessories CVTSIDE8 8" round transition to connect CVDUCT2 to VTD600P. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. 103/8" (264 mm) 123/4" (324 mm) 51/8" (130 mm) 11 5/8" (295 mm) VTD600P - 600 CFM 600 CFM flexible blower can be installed as an integrated or inline blower 11 5/8" (295 mm) 5" 123/4" (127 mm) (324 mm) 73/8" (187 mm) 51/4" (133 mm) measurements in inches (mm) measurements in inches (mm) Optional Accessories CVDUCT2 Rectangular 2 ft. long x 1 7/8 in deep x 19 in wide duct. CVDUCT2 transition required to directly connect CVDUCT2 to sides or rear of downdraft housing. Can be used as an extension to exhaust through a cabinet or wall, and can be cut to modify length. For use with installation of inline or remote blower applications with CVTSIDE6, CVTSIDE8, and CVTSIDE10. CVTRECT2 Transition required to connect CVDUCT2 rectangular duct to downdraft housing at left, right, or rear *For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. 154 NOTE: Some applications may require deeper cabinets. Refer to installation manual. Recirculation Kit UCVRECIRC Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction / electric cooktops only Replacement Charcoal Filter UCVFILTER Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit Downdraft Gas Cooktop Seal Trim Kit UCV36ST Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. Downdraft Gas Cooktop Seal Trim Kit UCV30ST Includes trim, seal, metal grill, and fasteners. Required for installations with 30" gas cooktops. EXTNCE5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. INSTALLATION Downdraft Flexible Blower Installation - Recirculation Example Required Blower 103/8" (264 mm) 123/4" (324 mm) 11 5/8" (295 mm) VTD600P - 600 CFM 600 CFM flexible blower can be installed as an integrated or inline blower 51/8" (130 mm) 5" 123/4" (127 mm) (324 mm) 11 5/8" (295 mm) 73/8" (187 mm) 51/4" (133 mm) measurements in inches (mm) measurements in inches (mm) Required Accessories Application - Allows for non-ducted downdraft installation by eliminating the need to exhaust to the exterior of the home* - Recirculation module and metal grill vent plate placement can be rotated for flexible exhaust placement - Elbow and duct work are not included - Use with induction / electric cooktops only Recirculation Kit UCVRECIRC Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction / electric cooktops only 14 1/2" (368) EXHAUST THROUGH CABINET SIDE Optional Accessories Replacement Charcoal Filter UCVFILTER Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit 15" (380) 3 1/2" (89) x 14 1/4" (362) EXHAUST OPENING DECORATIVE GRILLE Downdraft Gas Cooktop Seal Trim Kit UCV36ST Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. Measurements in inches (mm). EXHAUST THROUGH CABINET BACK 14 1/2" (368) 15" (380) Downdraft Gas Cooktop Seal Trim Kit UCV30ST Includes trim, seal, metal grill, and fasteners. Required for installations with 30" gas cooktops. EXTNCE5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. DECORATIVE GRILLE 3 1/2" (89) x 14 1/4" (362) EXHAUST OPENING *For front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone 155

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131

155
154
*For only front downward ducting applications, electrical panel must be remotely mounted. Electrical
panel can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension
cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer
to installation manual.
NOTE:
Some applications may require deeper cabinets. Refer to installation manual.
*For front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical
panel to downdraft. Refer to installation manual.
|
THERMADOR
|
VENTILATION
|
THERMADOR
|
VENTILATION
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone
Application
-
Side exhaust option to preserve precious kitchen storage space
or i± ducting is more convenient ±or this confguration*
-
A slim 2' rectangular duct is available to place ²exible blower in
areas such as unused corner in island or peninsula applications
- Blower must be accessible ±or maintenance
- Elbow and duct work are not included
Required Blower
VTD600P – 600 CFM
600 CFM ²exible blower can
be installed as an integrated
or inline blower
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
Optional Accessories
EXTNCE5
This cable extends 5 ±t. to move the electrical
panel out o± the way to o±±er ±ull installation
²exibility in any ducting scenario while installing
the downdra±t. Ability to connect two cables
together to make a 10 ±t. cable.
Replacement Charcoal Filter
UCVFILTER
Includes 1 replacement charcoal flter ±or
UCVRECIRC recirculation kit
Downdraft Gas Cooktop Seal Trim Kit
UCV36ST
Includes trim, seal, metal grill, and ±asteners.
Required ±or installations with 36" gas cooktops.
Recirculation Kit
UCVRECIRC
Includes 1 charcoal flter
and 1 metal grill vent plate
(blower sold separately).
Use with induction / electric
cooktops only
Required Accessories
CVTSIDE8
8" round transition to connect CVDUCT2
to VTD600P. Use with VTD600P blower as
an inline installation, and ducting with 8"
round duct connections.
CVTRECT2
Transition required to connect CVDUCT2
rectangular duct to downdra±t housing at
le±t, right, or rear
CVDUCT2
Rectangular 2 ±t. long x 1
7
/
8
in deep x 19
in wide duct. CVDUCT2 transition required
to directly connect CVDUCT2 to sides or
rear o± downdra±t housing. Can be used as
an extension to exhaust through a cabinet
or wall, and can be cut to modi±y length.
For use with installation o± inline or remote
blower applications with CVTSIDE6,
CVTSIDE8, and CVTSIDE10.
Downdraft Gas Cooktop Seal Trim Kit
UCV30ST
Includes trim, seal, metal grill, and ±asteners.
Required ±or installations with 30" gas cooktops.
INSTALLATION
Downdraft
±lexible Blower Installation – Side Exhaust with Slim 2' Rectangular Duct Example
Application
-
Allows ±or non-ducted downdra±t installation by eliminating the need
to exhaust to the exterior o± the home*
-
Recirculation module and metal grill vent plate placement can be
rotated ±or ²exible exhaust placement
- Elbow and duct work are not included
- Use with induction / electric cooktops only
EXHAUST
THROUGH
CABINET
SIDE
15"
(380)
14 1/2"
(368)
3 1/2" (89) x 14 1/4" (362)
EXHAUST OPENING
DECORATIVE
GRILLE
EXHAUST
THROUGH
CABINET
BACK
15"
(380)
14 1/2"
(368)
3 1/2" (89) x 14 1/4" (362)
EXHAUST OPENING
DECORATIVE
GRILLE
Measurements
in inches (mm).
Required Blower
VTD600P – 600 CFM
600 CFM ²exible blower can be
installed as an integrated or inline
blower
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
Required Accessories
Optional Accessories
EXTNCE5
This cable extends 5 ±t. to move the electrical panel
out o± the way to o±±er ±ull installation ²exibility in any
ducting scenario while installing the downdra±t. Ability
to connect two cables together to make a 10 ±t. cable.
Replacement Charcoal Filter
UCVFILTER
Includes 1 replacement charcoal flter ±or UCVRECIRC
recirculation kit
Downdraft Gas Cooktop Seal Trim Kit
UCV36ST
Includes trim, seal, metal grill, and ±asteners. Required
±or installations with 36" gas cooktops.
Recirculation Kit
UCVRECIRC
Includes 1 charcoal flter and
1 metal grill vent plate (blower
sold separately). Use with
induction / electric cooktops only
Downdraft Gas Cooktop Seal Trim Kit
UCV30ST
Includes trim, seal, metal grill, and ±asteners. Required
±or installations with 30" gas cooktops.
INSTALLATION
Downdraft
±lexible Blower Installation – Recirculation Example