ZyXEL U-336E User Manual - Page 117

Result Code Field Descriptions, Connect Strings for Error Corrected Connections

Page 117 highlights

Result Code Field Descriptions Field Name Error_Code Error_Control Data_Compression DCE_Speed DTE_Speed Possible Values NONE, ARQ LAPM, V42 (This field will not show if no error control is negotiated) V42b All possible DCE speeds supported All possible DTE speeds supported Connect Strings for Error Corrected Connections To enable the following numerical (ATV0) and verbose (ATV1) result codes when an error corrected connection is made, set S35 bit 7 to 1.(ATS35.7=1) Numerical V0 Verbose V1 50 CONNECT 51 CONNECT 1200 52 CONNECT 2400 53 CONNECT 4800 54 CONNECT 7200 55 CONNECT 9600 56 CONNECT 12000 57 CONNECT 14400 Numerical V0 58 59 60 61 62 63 64 65 Verbose V1 CONNECT 16800 CONNECT 19200 CONNECT 21600 CONNECT 24000 CONNECT 26400 CONNECT 28800 CONNECT 31600 CONNECT 33600 Status Registers & Result Codes 105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137

Status Registers & Result Codes
105
Result Code Field Descriptions
Field Name
Possible Values
Error_Code
NONE, ARQ
Error_Control
LAPM, V42
(This field will not show if no error control
is negotiated)
Data_Compression
V42b
DCE_Speed
All possible DCE speeds supported
DTE_Speed
All possible DTE speeds supported
Connect Strings for Error Corrected Connections
To enable the following numerical (ATV0) and verbose (ATV1)
result codes when an error corrected connection is made, set S35
bit 7 to 1.(
ATS35.7=1
)
Numerical V0
Verbose V1
Numerical V0
Verbose V1
50
CONNECT
58
CONNECT
16800
51
CONNECT
1200
59
CONNECT
19200
52
CONNECT
2400
60
CONNECT
21600
53
CONNECT
4800
61
CONNECT
24000
54
CONNECT
7200
62
CONNECT
26400
55
CONNECT
9600
63
CONNECT
28800
56
CONNECT
12000
64
CONNECT
31600
57
CONNECT
14400
65
CONNECT
33600