Campbell Scientific CSAT3 CSAT3 3-D Sonic Anemometer - Page 19

CSAT3 Outputs

Page 19 highlights

CSAT3 Three Dimensional Sonic Anemometer TABLE 5-8. FW05/FWC-L35 Fine Wire Thermocouple Description Signal High Signal Low Color Purple Red 6. CSAT3 Outputs The CSAT3 has three signal outputs: SDM, RS-232, and analog. Campbell Scientific recommends that the SDM output be used when ever possible, followed by RS-232, and finally analog. TABLE 6-1 summarizes the difference between the three output options. In general SDM communications has the following advantages: lowest CSAT3 current drain, best control and diagnostics, and highest data resolution. TABLE 6-1. CSAT3 Outputs Typical Current Drain @ 10 Hz External Trigger Source Output Dynamic Range Diagnostics Available SDM 51 mA @ 12 Vdc yes 19 bit yes RS-232 89 mA @ 12 Vdc yes 19 bit yes Analog 99 mA @ 12 Vdc no 12 bit no 6.1 SDM Output SDM is a Campbell Scientific communication protocol used between a Campbell Scientific datalogger and a smart sensor. TABLE 6-2 lists all the Campbell Scientific dataloggers that support SDM communications, along with the required datalogger OS/PROM and CSAT3 embedded code. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

CSAT3 Three Dimensional Sonic Anemometer
TABLE 5-8.
FW05/FWC-L35 Fine
Wire Thermocouple
Description
Color
Signal High
Purple
Signal Low
Red
6.
CSAT3 Outputs
The CSAT3 has three signal outputs:
SDM, RS-232, and analog.
Campbell
Scientific recommends that the SDM output be used when ever possible, followed
by RS-232, and finally analog.
TABLE 6-1 summarizes the difference between
the three output options.
In general SDM communications has the following
advantages:
lowest CSAT3 current drain, best control and diagnostics, and
highest data resolution.
TABLE 6-1.
CSAT3 Outputs
SDM
RS-232
Analog
Typical
Current Drain
@ 10 Hz
51 mA
@ 12 Vdc
89 mA
@ 12 Vdc
99 mA
@ 12 Vdc
External
Trigger
Source
yes
yes
no
Output
Dynamic
Range
19 bit
19 bit
12 bit
Diagnostics
Available
yes
yes
no
6.1
SDM Output
SDM is a Campbell Scientific communication protocol used between a
Campbell Scientific datalogger and a smart sensor.
TABLE 6-2 lists all the
Campbell Scientific dataloggers that support SDM communications, along with
the required datalogger OS/PROM and CSAT3 embedded code.