Campbell Scientific CSAT3 CSAT3 3-D Sonic Anemometer - Page 29

CR3000, CR1000, CR5000, CR800/850, CR9000X, CR23X and 21X Execution Interval

Page 29 highlights

CSAT3 Three Dimensional Sonic Anemometer CAUTION Command/Option 90, 91, 98, or 99 must not be used to collect data from a CSAT3 running a cold shifted calibration, see Section 11.2.1. Option 1, 2, 3, 5, 6, 10, 12, 15, 20, 30, and 60: "Set Execution Parameter" tells the CSAT3 which measurement parameters to use and what frequency to expect the measurement trigger from the datalogger. The datalogger Execution Interval and the appropriate CSAT3 Execution Parameter is summarized in TABLE 10-3 and TABLE 10-4. Option 61 and 62: "Set Execution Parameter" tells the CSAT3 to oversample (Section 8.1.2) the wind measurements at a rate of 60 Hz and expect a trigger at a rate of 10 Hz (option 61) or 20 Hz (option 62) from a CR3000, CR1000, CR5000, CR800/850, CR9000(X), CR23X or 21X datalogger. Option 51 and 52: "Set Execution Parameter" tells the CSAT3 to oversample (Section 8.1.2) the wind measurements at a rate of 48 Hz and expect a trigger at a rate of 8 Hz (option 51) or 16 Hz (option 52) from a CR10(X) datalogger. TABLE 10-3. CR3000, CR1000, CR5000, CR800/850, CR9000(X), CR23X and 21X Execution Interval and CSAT3 Execution Parameter Datalogger Execution Interval (seconds) 0.05 0.0625 0.075 0.0875 to 0.1 0.1125 to 0.1625 0.175 to 0.2 0.2125 to 0.325 0.3375 to 0.5 0.5125 to 1 Datalogger Execution Frequency (Hz) 20 16 13.333 11.429 to 10 8.889 to 6.154 5.714 to 5 4.706 to 3.077 2.963 to 2 1.951 to 1 CSAT3 Execution Parameter 20 15 12 10 6 5 3 2 1 TABLE 10-4. CR10(X) Execution Interval and CSAT3 Execution Parameter Datalogger Execution Interval (seconds) 0.0625 0.078125 0.09375 0.109375 to 0.15625 0.171875 to 0.1875 0.203125 to 0.328125 0.34375 to 0.5 0.515625 to 1 Datalogger Execution Frequency (Hz) 16 12.8 10.667 9.143 to 6.4 5.818 to 5.333 4.923 to 3.047 2.909 to 2 1.939 to 1 CSAT3 Execution Parameter 15 12 10 6 5 3 2 1 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

CSAT3 Three Dimensional Sonic Anemometer
Command/Option 90, 91, 98, or 99 must not be used to
collect data from a CSAT3 running a cold shifted
calibration, see Section 11.2.1.
Option 1, 2, 3, 5, 6, 10, 12, 15, 20, 30, and 60:
“Set Execution Parameter”
tells the CSAT3 which measurement parameters to use and what frequency to
expect the measurement trigger from the datalogger.
The datalogger Execution
Interval and the appropriate CSAT3 Execution Parameter is summarized in
TABLE 10-3 and TABLE 10-4.
Option 61 and 62:
“Set Execution Parameter” tells the CSAT3 to oversample
(Section 8.1.2) the wind measurements at a rate of 60 Hz and expect a trigger
at a rate of 10 Hz (option 61) or 20 Hz (option 62) from a CR3000, CR1000,
CR5000, CR800/850, CR9000(X), CR23X or 21X datalogger.
Option 51 and 52:
“Set Execution Parameter” tells the CSAT3 to oversample
(Section 8.1.2) the wind measurements at a rate of 48 Hz and expect a trigger
at a rate of 8 Hz (option 51) or 16 Hz (option 52) from a CR10(X) datalogger.
TABLE 10-3.
CR3000, CR1000, CR5000, CR800/850, CR9000(X), CR23X and 21X Execution Interval
and CSAT3 Execution Parameter
Datalogger Execution Interval
(seconds)
Datalogger Execution Frequency
(Hz)
CSAT3 Execution Parameter
0.05
20
20
0.0625
16
15
0.075
13.333
12
0.0875 to 0.1
11.429 to 10
10
0.1125 to 0.1625
8.889 to 6.154
6
0.175 to 0.2
5.714 to 5
5
0.2125 to 0.325
4.706 to 3.077
3
0.3375 to 0.5
2.963 to 2
2
0.5125 to 1
1.951 to 1
1
TABLE 10-4.
CR10(X) Execution Interval and CSAT3 Execution Parameter
Datalogger Execution Interval
(seconds)
Datalogger Execution Frequency (Hz)
CSAT3 Execution Parameter
0.0625
16
15
0.078125
12.8
12
0.09375
10.667
10
0.109375 to 0.15625
9.143 to 6.4
6
0.171875 to 0.1875
5.818 to 5.333
5
0.203125 to 0.328125
4.923 to 3.047
3
0.34375 to 0.5
2.909 to 2
2
0.515625 to 1
1.939 to 1
1
CAUTION
21