Compaq ProLiant 6500 Compaq Parallel Database Cluster Model PDC/O2000 for Orac - Page 60
Description of Failure, Failover Response, A Fibre Host Adapter connected
View all Compaq ProLiant 6500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
2-36 Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide Table 2-4 I/O Path Failure and Failover Scenarios in Redundant Fibre Channel Fabrics for Active/Standby Configurations With Two or More RA4000/RA4100 Arrays continued Description of Failure Failover Response The Fibre Channel cable None connection between the standby array controller in one RA4000/RA4100 Array and its Fibre Channel SAN Switch is broken. The Fibre Channel SAN Switch that is connected to the active array controller in each RA4000/RA4100 Array fails. Secure Path forces a complete failover to the standby I/O path components, including the standby Fibre Host Adapter in each node, the other Fibre Channel SAN Switch, the standby array controller in each RA4000/RA4100 Array, and Fibre Channel cables. The Fibre Channel SAN Switch None that is connected to the standby array controller in each RA4000/RA4100 Array fails. The Fibre Channel cable connection between the Fibre Channel SAN Switch that is connected to the active array controllers and a Fibre Host Adapter is broken. Secure Path forces a complete failover to the standby I/O path components, including the standby Fibre Host Adapter in each node, the other Fibre Channel SAN Switch, the standby array controller in the each RA4000/RA4100 Array, and Fibre Channel cables. The Fibre Channel cable None connection between the Fibre Channel SAN Switch that is connected to the standby array controllers and a Fibre Host Adapter is broken. A Fibre Host Adapter connected to the Fibre Channel SAN Switch that is connected to the active array controllers fails. Secure Path forces a complete failover to the standby I/O path components, including the standby Fibre Host Adapter in each node, the other Fibre Channel SAN Switch, the standby array controller in each RA4000/RA4100 Array, and Fibre Channel cables. A Fibre Host Adapter connected to None the Fibre Channel SAN Switch that is connected to the standby array controllers fails.