D-Link DSN-6110 User Manual for DSN-6110 & DSN-6110 with DSN-610 - Page 72

UPS column description, UPS Type, Shutdown, Battery, Level, Delay s, Status, Running, Unable

Page 72 highlights

First, connect the system and APC UPS via RS-232 for communication. Then set up the shutdown values (shutdown battery level %) when power is failed. UPS in other companies can work well, but they have no such communication feature with the system. (Figure 4.5.2.2: With Smart-UPS.) Figure 4.5.2.2 • UPS column description: UPS Type Shutdown Battery Level (%) Shutdown Delay (s) Shutdown UPS Status Select UPS Type. Choose Smart-UPS for APC, None for other vendors or no UPS. When below the setting level, system will shutdown. Setting level to "0" will disable UPS. If power failure occurs, and system power can not recover, the system will shutdown. Setting delay to "0" will disable the function. Select ON, when power is gone, UPS will shutdown by itself after the system shutdown successfully. After power comes back, UPS will start working and notify system to boot up. OFF will not. The status of UPS:  "Detecting..."  "Running"  "Unable to detect UPS"  "Communication lost"  "UPS reboot in progress" 72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

72
First, connect the system and APC UPS via RS-232 for communication. Then set up the
shutdown values (shutdown battery level %) when power is failed. UPS in other
companies can work well, but they have no such communication feature with the system.
Figure 4.5.2.2
(Figure 4.5.2.2: With Smart-UPS.)
UPS column description:
UPS Type
Select UPS Type. Choose Smart-UPS for APC, None for other
vendors or no UPS.
Shutdown
Battery
Level (%)
When below the setting level, system will shutdown. Setting
level to
“0”
will disable UPS.
Shutdown
Delay (s)
If power failure occurs, and system power can not recover, the
system will shutdown. Setting delay to
“0”
will disable the
function.
Shutdown
UPS
Select ON, when power is gone, UPS will shutdown by itself after
the system shutdown successfully. After power comes back, UPS
will start working and notify system to boot up. OFF will not.
Status
The status of UPS:
“Detecting…”
“Running”
“Unable to detect UPS”
“Communication lost”
“UPS reboot in progress”