Dell DL4000 Appliance Release Notes - Page 12
Error displayed when remounting volumes
View all Dell DL4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
NOTE: Do not launch the Core Console while the RUU is running. On upgrading the Core from AppAssure 5.4.3 to Rapid Recovery 6.0, the Core Console does not launch automatically Description Workaround/ Solution After upgrading the Core from AppAssure 5.4.3 to Rapid Recovery 6.0, you are prompted to restart the system. On restarting the system the startAA.vbs script does not open the Core Console but displays a Windows Script Host error. After upgrading to Rapid Recovery 6.0, manually start the Core Console by clicking the icon on the desktop. Error displayed when remounting volumes Description When recovering a DVM repository the following error is displayed: Failed read consistency lock on IsSpare_AC or MediaPresent_DiskDriveToStorageExtent_AC Association Cache. The error occurs when a repository was provisioned on several controllers and one of the mount points was removed. NOTE: Ensure you use the PERC H710P Mini controller to provision storage. Workaround/ Solution 1. Assign drive letters to volumes with storage locations of the repository. 2. Manually restore Core settings or Open Existing Repository through the Repositories pane specifying valid paths for repositories. Rapid Recovery 6.0 displays an error when ESX(i) host is offline Description Workaround After exporting ESX(i) virtual standby, if the state of ESX(i) host is offline, the error: Unable to connect to the remote server now is displayed. If an ESXi server backed Virtual Standbys exist, ensure all hosting ESXi servers are up and operational. 12