Dell Force10 E600i Quick Start Guide - Page 34

E600i ExaScale Environmental Parameters, E600i ExaScale AC Power Supply Unit Requirements, Parameter

Page 34 highlights

Parameter Maximum for fully loaded chassis Specifications 120 VAC powered: 4705W (16,065 BTU/hour) 200/240 VAC powered: 4250W (14,500 BTU/hour) DC powered: 2800W (9600 BTU/hour) E600i ExaScale Environmental Parameters Parameter Specifications Operating Temperature 32° to 104°F (0° to 40°C) Maximum altitude No performance degradation to 10,000 feet (3,048 meters) Relative humidity 5 to 85 percent, non-condensing Non-operating Temperature -40° to 158°F (-40° to 70°C) Maximum Altitude 15,000 feet (4,572 meters) Relative Humidity 5 to 95 percent, non-condensing E600i ExaScale AC Power Supply Unit Requirements Parameter Specifications Nominal input voltage 120 - 240 VAC 50/60 Hz Maximum AC Power Supply Input 16 A @ 100 VAC per module 12 A @ 200 VAC per module Maximum Thermal Output (3,172 W) 10,822 BTU/hour at 100/120 VAC Maximum Thermal Output (2,906 W) 9,914 BTU/hour at 200/240 VAC Maximum AC Supply Input Current 11.6 A @ 100 VAC (based on 2500 W output for 100/120V 9.7 A @ 120 VAC and 200/240V lines.) 8.0 A @ 200 VAC 6.7 A @ 240 VAC Maximum System Power Input 3.5 KVA @ 100/120 VAC 3.2 KVA @ 220/240 VAC 32 Installing the Hardware

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

32
Installing the Hardware
E600i ExaScale Environmental Parameters
E600i ExaScale AC Power Supply Unit Requirements
Maximum for fully loaded chassis
120 VAC powered: 4705W (16,065
BTU/hour)
200/240 VAC powered: 4250W (14,500
BTU/hour)
DC powered: 2800W (9600 BTU/hour)
Parameter
Specifications
Operating
Temperature
32° to 104°F (0° to 40°C)
Maximum altitude
No performance degradation to 10,000 feet (3,048 meters)
Relative humidity
5 to 85 percent, non-condensing
Non-operating
Temperature
-40° to 158°F (-40° to 70°C)
Maximum Altitude
15,000 feet (4,572 meters)
Relative Humidity
5 to 95 percent, non-condensing
Parameter
Specifications
Nominal input voltage
120 - 240 VAC 50/60 Hz
Maximum AC Power Supply Input
16 A @ 100 VAC per module
12 A @ 200 VAC per module
Maximum Thermal Output (3,172 W)
Maximum Thermal Output (2,906 W)
10,822 BTU/hour at 100/120 VAC
9,914 BTU/hour at 200/240 VAC
Maximum AC Supply Input Current
(based on 2500 W output for 100/120V
and 200/240V lines.)
11.6 A @ 100 VAC
9.7 A @ 120 VAC
8.0 A @ 200 VAC
6.7 A @ 240 VAC
Maximum System Power Input
3.5 KVA @ 100/120 VAC
3.2 KVA @ 220/240 VAC
Parameter
Specifications