Dell Force10 E600i Quick Start Guide - Page 34
E600i ExaScale Environmental Parameters, E600i ExaScale AC Power Supply Unit Requirements, Parameter
View all Dell Force10 E600i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Parameter Maximum for fully loaded chassis Specifications 120 VAC powered: 4705W (16,065 BTU/hour) 200/240 VAC powered: 4250W (14,500 BTU/hour) DC powered: 2800W (9600 BTU/hour) E600i ExaScale Environmental Parameters Parameter Specifications Operating Temperature 32° to 104°F (0° to 40°C) Maximum altitude No performance degradation to 10,000 feet (3,048 meters) Relative humidity 5 to 85 percent, non-condensing Non-operating Temperature -40° to 158°F (-40° to 70°C) Maximum Altitude 15,000 feet (4,572 meters) Relative Humidity 5 to 95 percent, non-condensing E600i ExaScale AC Power Supply Unit Requirements Parameter Specifications Nominal input voltage 120 - 240 VAC 50/60 Hz Maximum AC Power Supply Input 16 A @ 100 VAC per module 12 A @ 200 VAC per module Maximum Thermal Output (3,172 W) 10,822 BTU/hour at 100/120 VAC Maximum Thermal Output (2,906 W) 9,914 BTU/hour at 200/240 VAC Maximum AC Supply Input Current 11.6 A @ 100 VAC (based on 2500 W output for 100/120V 9.7 A @ 120 VAC and 200/240V lines.) 8.0 A @ 200 VAC 6.7 A @ 240 VAC Maximum System Power Input 3.5 KVA @ 100/120 VAC 3.2 KVA @ 220/240 VAC 32 Installing the Hardware