Dell Force10 E600i Quick Start Guide - Page 37
E1200i ExaScale Environmental Parameters, E1200i ExaScale Power Requirements, Thermal Output
View all Dell Force10 E600i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Parameter E1200i AC Specifications E1200i DC Specifications Weight fully loaded (backplane, air filter, 2 fan trays, 10 SFM3s, RPMs, and 14 line cards) 422 pounds (approx.) (191.2 kg) 319 pounds (approx.) (144.70 kg) Thermal Output Maximum (fully-loaded chassis with 10-port 10GE line cards) 18,368 BTU/hr 16,446 BTU/hr Minimum (chassis with one 2,313 BTU/hr 10-port 10GE line card) 1,997 BTU/hr E1200i ExaScale Environmental Parameters Parameter Specifications Operating Temperature 32° to 104°F (0° to 40°C) Maximum altitude No performance degradation to 10,000 feet (3,048 meters) Relative humidity 5 to 85 percent, non-condensing Shock Designed to meet Telcordia GR-63 CORE Vibration Designed to meet Telcordia GR-63 CORE Non-operating Temperature -40° to 158°F (-40° to 70°C) Maximum Altitude 15,000 feet (4,572 meters) Relative Humidity 5 to 95 percent, non-condensing Vibration Bellcore GR-63 E1200i ExaScale Power Requirements Parameter E1200i AC Specifications Nominal input voltage 200-240 VAC 50/60 Hz Maximum Power Consumption 6,634 W E1200i DC Specifications -44 to 60 VDC 5,400 W Installing the Hardware 35