E1200i TeraScale Power Requirements, E1200i ExaScale Chassis Physical Design, Non-operating, Parameter
View all Dell Force10 E600i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Parameter Vibration Non-operating Temperature Maximum Altitude Relative Humidity Vibration Specifications Designed to meet Telcordia GR-63 CORE -40° to 158°F (-40° to 70°C) 15,000 feet (4,572 meters) 5 to 95 percent, non-condensing Bellcore GR-63 E1200i TeraScale Power Requirements Parameter E1200i AC Specifications Nominal input voltage 200-240 VAC 50/60 Hz Maximum Power Consumption 5,734 @ 200/240 VAC Maximum Thermal 18,710 BTU/hour (5,484 W) Output E1200i DC Specifications -44 to 60 VDC 5,210 W 16,924 BTU/hour (4,910 W) Maximum Input Current Maximum System Power Input (per power supply) 15.0 A @ 200 VAC 12.5 A @ 240 VAC 5.8 KVA @ 200/240 VAC (per DC PEM) 150 A E1200i ExaScale Chassis Physical Design Parameter E1200i AC Specifications E1200i DC Specifications Height 42 inches (106.68 cm) 36.75 inches (93.35 cm) Width 17.40 inches (44.20 cm) 17.40 inches (44.20 cm) Depth (without cable management system) 22.25 inches (56.51 cm) 21.25 inches (53.98 cm) Chassis weight with factory- 139 pounds (approx.) installed components (63.05kg) (backplane and air filter) 97 pounds (approx.) (44.00 kg) 34 Installing the Hardware