Dell OptiPlex GL Service Manual - Page 43
System HALTED, Incorrect Time or Date
View all Dell OptiPlex GL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Table 3-2. System Error Messages (continued) Message Definition Probable Causes Sector not found MS-DOS unable to Defective sectors on dis- locate sector on diskette kette or hard-disk drive. or hard-disk drive. Seek error MS-DOS unable to locate specific track on diskette or hard-disk drive. Defective diskette or hard-disk drive. Seek operation failed System could not find Faulty diskette or hardparticular address mark disk drive. on disk. Shutdown fail- System board chip ure faulty. Defective system board. Terminator/ processor card not installed! System HALTED! System does not have terminator or add-in card. Terminator or add-in card improperly installed, or no card installed. Time-of-day Backup battery low. clock stopped Defective battery or faulty chip (defective system board). Time-of-day not set Time or Date settings in System Setup program incorrect, or backup battery bad. Incorrect Time or Date settings, or defective backup battery. Timer chip counter 2 failed Timer circuit on system Defective system board. board malfunctioning. Unexpected interrupt in protected mode Keyboard/mouse controller malfunctioning, or one or more DIMMs improperly seated. Improperly seated DIMMs or faulty keyboard/mouse controller chip (defective system board). WarningThermal probes failed At system start-up, BIOS detected that one or both thermal probes are nonoperational. Defective system board. Beep Codes and Error Messages 3-9