Epson TM-U950P Specifications - Page 32

Configuration

Page 32 highlights

2. CONFIGURATION 2.1 Interface 2.1.1 RS-232 serial interface 1) Specifications Data transmission: Serial Synchronization: Asynchronous Handshaking: DTR/DSR or XON/XOFF control Signal levels: MARK = -3 to -15 V: Logic "1" SPACE = +3 to +15 V: Logic "0" Stop bits: 1 or more Connector (printer side): Female DSUB-25 pin connector The data word length, baud rate, and parity depend on the DIP switch settings. (Refer to Section 3.3.3.) 2) Switching between on-line and off-line The printer does not have an on-line/off-line switch. The printer goes off-line: ù Between when the power is turned on (including reset using the interface) and when the printer is ready to receive data ù During the self-test ù When the cover is open ù During paper feeding using the paper feed switch ù When the printer stops printing due to a paper-end (if enabled by ESC c 4) ù When an error has occurred 3) Interface connector terminal assignments and signal functions are described in Table 2.1.1. TITLE EPSON TM-U950/U950P Specification (STANDARD) SHEET NO. REVISION A NEXT 164 SHEET 153

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

EPSON
TITLE
SHEET
REVISION
NO.
SHEET
NEXT
A
TM-U950/U950P
Specification
(STANDARD)
2. CONFIGURATION
2.1 Interface
2.1.1 RS-232 serial interface
1) Specifications
Data transmission:
Serial
Synchronization:
Asynchronous
Handshaking:
DTR/DSR or XON/XOFF control
Signal levels:
MARK = -3 to -15 V:
Logic "1"
SPACE = +3 to +15 V: Logic "0"
Stop bits:
1 or more
Connector (printer side):
Female DSUB-25 pin connector
The data word length, baud rate, and parity depend on the DIP switch settings.
(Refer to Section 3.3.3.)
2) Switching between on-line and off-line
The printer does not have an on-line/off-line switch.
The printer goes off-line:
ø
Between when the power is turned on (including reset using the interface) and when the printer is
ready to receive data
ø
During the self-test
ø
When the cover is open
ø
During paper feeding using the paper feed switch
ø
When the printer stops printing due to a paper-end (if enabled by
ESC c 4
)
ø
When an error has occurred
3) Interface connector terminal assignments and signal functions are described in Table 2.1.1.
13
14