HP StorageWorks B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 10.4.5 Release Notes Part Number: 5697-0846 Ninth edition: February 2011 - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 2
Legal and notice information © Copyright 2009-2011 Hewlett-Packard Development Company, L.P. © Copyright 2009-2011 Brocade Communications Systems, Incorporated Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation. - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 3
including: • Support for new hardware • Feature enhancements across multiple platforms • Integrated SMI DCFM 10.4 added support for the new HP StorageWorks DC SAN SMI-only installation option • FCoE: Support for HP StorageWorks 2408 FCoE Converged Network Switch in Access Gateway mode B-series Data - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 4
) Link Configuration • Display BP Link Status • Dynamic view update on Encryption Center and LUN dialog box • Provide commit state on target container • Show all rekey sessions for LUN on view • Export Certificate support FCIP enhancements • Support for IPSec for the HP StorageWorks 1606 Extension - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 5
) HBA Management Updates to Property Sheets Switch Config- uration operations (switch enable/disable, port enable/disable) • Implemented the following end user Requests For Enhancements (RFEs): • Switch SS folder name change as • Copying switch/host support - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 6
based routing for lossless DLS • HP StorageWorks DC SAN Director Switch Multiprotocol Extension Blade support in VF dialog box Supported switches and firmware Table 1 lists switches and firmware families supported with version 10.4.5. This does not imply that all firmware versions listed in the left - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 7
Table 1 Supported switches and firmware Switch firmware Switch/Director Fabric OS 5.0.x, 5.1.x, 5.2.x, 5.3.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, and 6.4.x HP StorageWorks SAN Switch 2/32 (Brocade 3900) HP StorageWorks SAN Switch 2/8V (Brocade 3250) HP StorageWorks SAN Switch 2/16V (Brocade 3850) HP - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 8
HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000)11 HP StorageWorks 1606 Extension SAN Switch (Brocade 7800)9 Fabric OS 5.2.x, 5.3.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, and 6.4.x Brocade 4Gb SAN Switch for HP Fabric OS 6.1.2_cee1 or later. Support for this switch in DCFM 10.1.x is for - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 9
) • Windows 2008 Std (x86 32-bit) • Windows 7 Professional edition • RedHat AS 4.0 (x86 32-bit) Supported feature summary for DCFM Table 3 lists the DCFM supported features. Table 3 Supported DCFM features Feature DCFM Professional DCFM Professional Plus Number of fabrics 1 4 Type of fabric - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 10
, or Professional User Manual for details on the following notes. These documents can be downloaded from the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html Under Support, click HP Support & Documents, and then click Manuals. Under User guide, select the - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 11
certain fabric interoperability support, and by be consumed by mid-2010. Brocade factory shipments of switches after this time will have WWNs IP address to download the correct version, which is bundled with the DCFM server. NOTE: If you installed JRE 1.6.0 Update 16, do not use the Java auto-updater - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 12
services must be started manually on both Linux and Solaris systems. Otherwise, the DCFM client fails to launch. Event priority mismatch Error to download a configuration from one virtual switch to another virtual switch and the Fabric IDs do not match, the download fails. Switch name update delay - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 13
.4.0, all historical data is truncated with respect to the default samples, and the aging configuration is not migrated. Encryption configuration has limited support The current commit limitation of a total of 25 LUN transactions (add, update, and remove) can cause delays in registering changes for - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 14
remove the odbc folder from the DCFM location and the ODBC driver shortcut menu item will not be removed. HP recommends that you remove it manually. Configuring OBDC connection manually With DCFM 10.0.x and later, when the configuration page is skipped during ODBC installation, you can create DSN at - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 15
indicates the supported range of 0x00000000 to 0xFFFFFFFF). Configuring this setting with any other value will interfere with the FICON Tape Write pipelining settings. This is applicable to versions 10.4.0, 10.4.1, 10.4.2, and 10.4.5. Displaying logical switches Logical switches that are created - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 16
further details, see the "Changing the database user password" section in the DCFM User Manual, Chapter 1 "Getting Started." Access Control List display Access Control lists are not displayed in the ACL tab of the Edit Switch dialog box for a CEE switch with Fabric OS versions 6.3.1 and earlier. SMI - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 17
router in the Router Configuration dialog box. So the user cannot configure EX_Ports for the Encryption Switch using DCFM. Error message is not shown for FC Ports when seclevel is set in the switch Once the switches are discovered and seclevel is set in the switch on launching Realtime Graph dialog - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 18
and Transition Guide or the Data Center Fabric Manager Enterprise, Professional Plus, or Professional user manuals. These documents can be downloaded from the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html Under Support, click HP Support & Documents - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 19
html 2. Under Support, click HP Support & Documents, and then click Download drivers and software. 3. Under Select your product, select HP StorageWorks B-series Data Center Fabric Manager Enterprise Software. 4. Under Select operating system, click Cross operating system (BIOS, Firmware, Diagnostics - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 20
Guide. • Ensure that the network environment does not have any firewall protection between the client, server, and switches. If there is a firewall, ensure that rules are set supported. See Table 2 on page 9. • DCFM 10.4.5 was tested using English, Japanese, and German languages and is supported - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 21
Profile for your configuration, on the Inbound connections list, select Allow. NOTE: Windows Firewall with Advanced Security supports separate profiles (sets of firewall and connection security rules) for computers that are members of a domain, or connected to a private or public network. Once the - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 22
the supported clients as detailed above for the Installation Guide. Brocade document: DCFM Professional User Manual (Publication Number 53-1001773-01) On page 47, in the Host discovery section, edit the "Configuring virtual machine credentials" procedure as follows: 1. Select Discover > Setup. The - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 23
Agent is configured to advertise itself as a Service Agent (SA). The advertised SLP template shows its location (IP address) and the WBEM Services it supports. The default advertised WBEM services show the Management application SMI Agent: • Accepts WBEM requests over HTTP without SSL on TCP port - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 24
/doc/html/UsersGuide/index.html. Verifying SLP service installation and operation on UNIX systems To verify: 1. Open a command window. 2. Type % su root and press Enter to become the root user. 3. Type # Management_Application/cimom/bin/slptool findsrvs service:service-agent and then press Enter to - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 25
configured client protocol adapters: • Type # Management_Application/cimom /bin/slptool findattrs service:wbem:http://IP_Address:Port and press Enter. • Type # Management_Application/cimom /bin/slptool findattrs service:wbem:https://IP_Address:Port and press Enter. NOTE: IP_Address:Port is the IP - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 26
credentials" procedure as detailed above for the Professional User Manual. On page 171, in the SMI Agent configuration section, add the Service Location Protocol (SLP) support information as detailed above for the Professional Plus User Manual. DCFM 10.4.0 fixes Table 4 lists the defects that - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 27
in DCFM 10.4.0. Backend error is being displayed on creating a Profile/Map on the HP StorageWorks 2408 FCoE Converged Network switch or DC SAN Fixed in DCFM 10.4.0. Director Switch 10/24 FCoE blade. Unable to replicate the "All Configurations" from one 2408 FCoE switch to a different 2408 FCoE - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 28
configuration to 2408 FCoE switch. Fixed in DCFM 10.4.0. Activating the IPL PDCM configuration fails with DCFM with error "PDCM_002 :Unknown error, Cannot set CUP Configuration the Professional edition, user is able to select the Server IP in the Server IP Configuration page and hence remote client - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 29
of the circuits in the Switch, leading to the user being unable Fixed in DCFM 10.4.0. to create a new tunnel with the deleted IP addresses. Port List on Mi10k Element Manager is not updating after the port is blocked via RMC. Fixed in DCFM 10.4.0. Firmware upgrade via the Element Manager - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 30
to upgrade: Change the port name from the default view (View All)/ delete all unmonitored fabrics. Fixed in DCFM 10.4.0. Unable to launch Web Tools from DCFM. Fixed in DCFM 10.4.0. HP StorageWorks Encryption SAN switch was in an Encryption Group configured with Key Vault 1 initially but later - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 31
active zone config after upgrade from EFCM 9.7.3 to DCFM 10.3.0. Fixed in DCFM 10.4.0. Minimum bandwidth should be 10 MB/s for the tunnels created in HP StorageWorks 1606 Extension SAN switch and DC SAN Director Fixed in DCFM 10.4.0. Multiprotocol Extension blade. No privileged user for Zoning - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 32
some time. Values will then be updated. Fixed in DCFM 10.4.0 DCFM cannot configure D,I Zone an Mi10K configured for 239 DIDs. Error message states D,I zoning is not supported. Fixed in DCFM 10.4.0. After creating a new tunnel, tunnel has not been shown at the Switch- Workaround prior to upgrade - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 33
in DCFM 10.4.0. DCFM services will not install. Fixed in DCFM 10.4.0. When a logical switch is edited through DCFM, the GUI takes a long time to update. Fixed in DCFM 10.4.0. In User Management dialog box, EMail Notification column is not sorted correctly when users by ID, Description, EMail - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 34
dialog box, information about Select Switch Two button is missing Fixed in DCFM 10.4.0. Configure Storage Encryption Fails When Target Info Entered Without ":", and user will not be able to create containers. Fixed in DCFM 10.4.0. FICON Emulation settings validation error message pops up in - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 35
may be invalid" when the user fails to provide the configured Auth\ priv passwords in DCFM. Workaround prior to upgrade: Provide all the configured v3 credentials when discovering the switch. Fixed in DCFM 10.4.0. Delete of a logical switch failed, server errors about moving port from and to - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 36
Low disk space error message is shown while trying to import firmware even though 30GB disk multiple circuits will not be shown to the user. Fixed in DCFM 10.4.0. Unable to configure weekly / monthly switch . Fixed in DCFM 10.4.0. Installation guide has incorrect system requirements for SUSE - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 37
the merge OK, but no zones were configured - set to allow all access. Fixed in DCFM 10.4.0. Event policy, Type "ISL Offline," is triggered for the F_Ports. Fixed in DCFM 10.4.0. Error message is displayed when valid physical ports from Logical switch is selected for Trace Route operation. Fixed - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 38
configuration. Workaround prior to upgrade: User has to delete all the zones which contain D,P members from the Global zone Library. Fixed in DCFM 10.4.0. IP address updated in the remote client is not getting updated in the local client and the switch is set to hide all, but the phantom switch is - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 39
with green icon in Activate Zone Config dialog box for Fabric OS less than 6.2.0. Fixed in DCFM 10.4.0. Enabling a tunnel failed with the message Tunnel Admin Status cannot be set. error: failed to modify. Fixed in DCFM 10.4.0. Not able to manage the switch in server A although the fabric is - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 40
do not the client to see the changes. dynamically update in the other client. Fixed in DCFM 10.4.0. dialog box. Fixed in DCFM 10.4.0. Improve LIC error message when there is no fabric being managed by 1606 extension SAN switch and multiprotocol extension blade. Fixed in DCFM 10.4.0. Configuring - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 41
what is on the switch. Fixed in DCFM 10.4.0. FICON Emulation values are not in sync with CLI; that is, CLI shows the FICON values, but application does not show any value. Fixed in DCFM 10.4.0. Error message is given while trying to download firmware when External FTP is configured on the same - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 42
group and DC SAN Backbone Director in switch group Icons are shown alike in topology and device tree when look and feel Fixed in DCFM 10.4.0. is set as Default/Small/Large. "Failed to get FCIP circuit configuration: IPC error, please retry the command" error has been given in FCIP Tunnel \ Circuit - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 43
In Connection Properties table, E_Port of a 1606 extension SAN switch Relaunching the client. is shown as gigE port. Fixed in DCFM 10.4.0. Incorrect number of edits is shown in the error message when Compare Merge dialog box is opened from the Activate Zone Config dialog box. Workaround prior to - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 44
switch level. Fixed in DCFM 10.4.0. Accept changes is not working, support save did not complete even after 5 hours, Remote Client is blank. Scheduled configuration for Technical support switch/blade public certs exported during setup are actually CSR and needs to be signed before the switches - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 45
GigE ports with one FCIP Tunnel in 1606 extension SAN switches. Fixed in DCFM 10.4.0. Web Tools window comes up with invalid session when launched for Logical Switches. Fixed in DCFM 10.4.0. Import of firmware to repository fails with two different error messages that are not appropriate. Fixed - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 46
not reflecting the Host name set in DCFM and instead showing the same value as the Network address field. Workaround prior to host name set in DCFM. Fixed in DCFM 10.4.0. In master log, after highlighting an event from a VF enabled switch, the in a large fabric configuration. Fixed in DCFM - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 47
Network IDs has no value for the virtual switches. Fixed in DCFM 10.4.0. Error for M-model switches. Fixed in DCFM 10.4.0. Brocade_SwitchFCPort.OperationalStatus is set to 15 fabric through Configuration Tool after discovering a host. Workaround prior to upgrade: Add the switch through DCFM - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 48
default) fresh install, user fails to login. Workaround prior to upgrade: Restart the server. Fixed in DCFM 10.4.0. Error message does not give sufficient information for the user get updated with the latest information from the switch in a reasonable time when there is any SNMP configuration - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 49
state. Fixed in DCFM 10.4.0. Ambiguous Error message is displayed during firmware import to the repository when there is a low disk space. Fixed in DCFM 10.4.0. Topology is not shown with -ve symbol for switches and end devices which made offline during migration from DCFM 10.1.x to DCFM - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 50
: Tree, it is not getting updated unless Client is relaunched or HBA is re- Relaunch Client; Rediscover HBA. discovered. Fixed in DCFM 10.4.0. NPE is given when the user tries to launch EWS for M model switch from the fabric tree. Fixed in DCFM 10.4.0. An Error message is displayed stating CAL - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 51
Fixed in DCFM 10.4.1. Properties with wrong values are returned when a switch with firmware version 6.1.x or earlier is managed with invalid SNMP credentials. User may not be able to retrieve the correct Fabric WWN, switch information like vendor, model and serial number. Zoning operation cannot be - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 52
switch is discovered via ipv6 address. Fixed in DCFM 10.4.1a. CEE Maps or Ethernet Ports not returned when using Brocade_CEEMapOnEthernetPort. User update in a timely manner. User will not be able to view the configured DCFM 10.4.2. When configuring multiple LUN settings changing from cleartext to - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 53
the error message multiple AGs connected to different switches set of ports. Fixed in DCFM 10.4.3. Technical Support data collection fails for switches of a Fabric whose seed switch is running a firmware version lower than v6.2.x or a seed switch that is upgraded to 6.2.x and not rebooted. The user - HP 1606 | HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 54
upgrade: Users can manually set the HP StorageWorks 4/256 SAN Director is discovered, the DCFM management service periodically stops and restarts until the server runs out of disk space. Fixed in DCFM 10.4.5 Backup with a network drive fails after a server reboot. Fixed in DCFM 10.4.5 Problems
HP StorageWorks
B-series Data Center Fabric Manager
Enterprise, Professional Plus, and
Professional
10.4.5 Release Notes
Part Number: 5697-0846
Ninth edition: February 2011