HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 42
Workaround prior to upgrade, The structure of the view is not persisted in the device tree and not
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Closed defect summary Solution No proper error message is shown when trying to activate the zone with seed switch in a pure MEOS fabric that is unreachable. User will not know why the zone activation/deactivation failed. Workaround prior to upgrade: Change the seed switch or wait for seed switch auto failover in case of seed switch unreachable, change the credentials in case of authentication failure. Fixed in DCFM 10.4.0. Error message does not give sufficient information for the user when trying to activate zones with port numbers > 255 in IM2. Workaround prior to upgrade: Activation would get successful, if only ports lesser than 256 are selected. Fixed in DCFM 10.4.0. CPU utilization for the process (dbsrv10.exe) is very high (about 95100%) when there are a number of large fabrics (more than 100 switches). Workaround prior to upgrade: Restart the client. Fixed in DCFM 10.4.0. DCFM fails to delete an ACL policy from a CEE capable Switch. Fixed in DCFM 10.4.0. Switches discovered through SNMPV1 are getting listed in the Informs table, which is supported only for switches discovered through SNM- Fixed in DCFM 10.4.0. PV3. In Pure MEOS fabric, the Plus symbol is not removed from the device tree after giving accept changes. Workaround prior to upgrade: Launch a new client. Fixed in DCFM 10.4.0. DCFM does not show ISLs to connected switches in domainoffset mode 192(0xc0). Fixed in DCFM 10.4.0. The structure of the view is not persisted in the device tree and not in sync with the topology, when going to another view and coming back. Fixed in DCFM 10.4.0. A few entities are not updated while creating a Standard ACL. Fixed in DCFM 10.4.0. HBA in host group and DC SAN Backbone Director in switch group Icons are shown alike in topology and device tree when look and feel Fixed in DCFM 10.4.0. is set as Default/Small/Large. "Failed to get FCIP circuit configuration: IPC error, please retry the command" error has been given in FCIP Tunnel \ Circuit configuration report, while creating a tunnel between DC SAN Backbone Director switches. Fixed in DCFM 10.4.0. Swap blade operation fails at the first time, but succeeds in the next attempt. Fixed in DCFM 10.4.0. Not Getting VM properties when opening the Properties dialog box from HBA and HBA port. Fixed in DCFM 10.4.0. HBA discovered as part of a fabric is shown in the fabric but has no connection to anything in the fabric. Fixed in DCFM 10.4.0. 42