HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 42

Workaround prior to upgrade, The structure of the view is not persisted in the device tree and not

Page 42 highlights

Closed defect summary Solution No proper error message is shown when trying to activate the zone with seed switch in a pure MEOS fabric that is unreachable. User will not know why the zone activation/deactivation failed. Workaround prior to upgrade: Change the seed switch or wait for seed switch auto failover in case of seed switch unreachable, change the credentials in case of authentication failure. Fixed in DCFM 10.4.0. Error message does not give sufficient information for the user when trying to activate zones with port numbers > 255 in IM2. Workaround prior to upgrade: Activation would get successful, if only ports lesser than 256 are selected. Fixed in DCFM 10.4.0. CPU utilization for the process (dbsrv10.exe) is very high (about 95100%) when there are a number of large fabrics (more than 100 switches). Workaround prior to upgrade: Restart the client. Fixed in DCFM 10.4.0. DCFM fails to delete an ACL policy from a CEE capable Switch. Fixed in DCFM 10.4.0. Switches discovered through SNMPV1 are getting listed in the Informs table, which is supported only for switches discovered through SNM- Fixed in DCFM 10.4.0. PV3. In Pure MEOS fabric, the Plus symbol is not removed from the device tree after giving accept changes. Workaround prior to upgrade: Launch a new client. Fixed in DCFM 10.4.0. DCFM does not show ISLs to connected switches in domainoffset mode 192(0xc0). Fixed in DCFM 10.4.0. The structure of the view is not persisted in the device tree and not in sync with the topology, when going to another view and coming back. Fixed in DCFM 10.4.0. A few entities are not updated while creating a Standard ACL. Fixed in DCFM 10.4.0. HBA in host group and DC SAN Backbone Director in switch group Icons are shown alike in topology and device tree when look and feel Fixed in DCFM 10.4.0. is set as Default/Small/Large. "Failed to get FCIP circuit configuration: IPC error, please retry the command" error has been given in FCIP Tunnel \ Circuit configuration report, while creating a tunnel between DC SAN Backbone Director switches. Fixed in DCFM 10.4.0. Swap blade operation fails at the first time, but succeeds in the next attempt. Fixed in DCFM 10.4.0. Not Getting VM properties when opening the Properties dialog box from HBA and HBA port. Fixed in DCFM 10.4.0. HBA discovered as part of a fabric is shown in the fabric but has no connection to anything in the fabric. Fixed in DCFM 10.4.0. 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Solution
Closed defect summary
Workaround prior to upgrade:
Change the seed switch or wait for
seed switch auto failover in case of
seed switch unreachable, change the
credentials in case of authentication
failure.
Fixed in DCFM 10.4.0.
No proper error message is shown when trying to activate the zone
with seed switch in a pure MEOS fabric that is unreachable. User will
not know why the zone activation/deactivation failed.
Workaround prior to upgrade:
Activation would get successful, if only
ports lesser than 256 are selected.
Fixed in DCFM 10.4.0.
Error message does not give sufficient information for the user when
trying to activate zones with port numbers > 255 in IM2.
Workaround prior to upgrade:
Restart
the client.
Fixed in DCFM 10.4.0.
CPU utilization for the process (dbsrv10.exe) is very high (about 95-
100%) when there are a number of large fabrics (more than 100
switches).
Fixed in DCFM 10.4.0.
DCFM fails to delete an ACL policy from a CEE capable Switch.
Fixed in DCFM 10.4.0.
Switches discovered through SNMPV1 are getting listed in the Informs
table, which is supported only for switches discovered through SNM-
PV3.
Workaround prior to upgrade:
Launch
a new client.
Fixed in DCFM 10.4.0.
In Pure MEOS fabric, the Plus symbol is not removed from the device
tree after giving accept changes.
Fixed in DCFM 10.4.0.
DCFM does not show ISLs to connected switches in domainoffset mode
192(0xc0).
Fixed in DCFM 10.4.0.
The structure of the view is not persisted in the device tree and not in
sync with the topology, when going to another view and coming back.
Fixed in DCFM 10.4.0.
A few entities are not updated while creating a Standard ACL.
Fixed in DCFM 10.4.0.
HBA in host group and DC SAN Backbone Director in switch group
Icons are shown alike in topology and device tree when look and feel
is set as Default/Small/Large.
Fixed in DCFM 10.4.0.
Failed to get FCIP circuit configuration: IPC error, please retry the
command
error has been given in FCIP Tunnel \ Circuit configuration
report, while creating a tunnel between DC SAN Backbone Director
switches.
Fixed in DCFM 10.4.0.
Swap blade operation fails at the first time, but succeeds in the next
attempt.
Fixed in DCFM 10.4.0.
Not Getting VM properties when opening the Properties dialog box
from HBA and HBA port.
Fixed in DCFM 10.4.0.
HBA discovered as part of a fabric is shown in the fabric but has no
connection to anything in the fabric.
42