HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 36
FCIP Tunnel\Circuit Configuration Report dialog box., DC SAN Backbone Director
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Closed defect summary Solution After adding single side tunnel on DC SAN Backbone Director with multiprotocol router blade or 4/256 Director with Multiprotocol Router blade, VE port number not shown along with Tunnel ID. Upon adding second side tunnel for that one side tunnel error has been given in FCIP Tunnel\Circuit Configuration Report dialog box. Workaround prior to upgrade: Add the double side tunnel between two DC SAN Backbone Director with multiprotocol router blades or two 4/256 Director with Multiprotocol Router blades. You should now be able to configure the tunnel. Fixed in DCFM 10.4.0. Copied Configuration is not listed in the Product/port tree but successfully saved in the switch. Workaround prior to upgrade: Close the Configure Allow / Prohibit matrix and open it again. Fixed in DCFM 10.4.0. Some port fencing policies not applied to the 1606 extension SAN switch. The "+" sign is shown at the wrong time. The ">" is shown at the wrong level. Fixed in DCFM 10.4.0. An alert message is shown in the Zoning dialog box when the TI zone modification is done before activation. Fixed in DCFM 10.4.0. Low disk space error message is shown while trying to import firmware even though 30GB disk space is available in installation directory in Fixed in DCFM 10.4.0. Windows Vista OS. Enable informs on a fabric with no informs capable switches hangs, client must be killed. Fixed in DCFM 10.4.0. Duplicate circuits have been shown in the Circuits TAB of FCIP Tunnels dialog box when multiple circuits for the same tunnel are created. Workaround prior to upgrade: Close and reopen the FCIP Tunnels dialog box and observe that now multiple circuits will not be shown to the user. Fixed in DCFM 10.4.0. Unable to configure weekly / monthly switch scheduled backup for the current day with a lesser time than the current system time Workaround prior to upgrade: Schedule daily backup. Fixed in DCFM 10.4.0. The image bundled with DVD HTML displays "Professional Edition",this needs to be replaced with the latest image. Fixed in DCFM 10.4.0. Installation guide has incorrect system requirements for SUSE Linux. Fixed in DCFM 10.4.0. Additional fields are shown in Access Gateway property sheet on AG device 2408 FCoE switch. Fixed in DCFM 10.4.0. DC SAN Backbone Director discovery fails intermittently (1 out of 10 times) giving the error message "Discovery Failed." Fixed in DCFM 10.4.0. Fabric disappears in the Client after performing unmonitor and monitor operation in mixed fabric. Workaround prior to upgrade: Relaunch the client to see the fabric in Topology. Fixed in DCFM 10.4.0. Product List: Serial Number is displayed incorrectly for OEM customized switches. Fixed in DCFM 10.4.0. 36