HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 14

HP StorageWorks DC SAN Director support in Professional Plus

Page 14 highlights

Gateway is not displayed in the Topology. HP recommends that you disable F_Port trunking on the switch before connecting it to the Access Gateway. VMware firewall settings may require HCM agent to be restarted If the firewall settings on port 514 changed in VMware, the HCM Agent must be restarted. VMware (ESX 3.5 & 4) blocks the Syslog outgoing port 514 by default. If you are using a Syslog Host configuration or HCM as part of DCFM, the firewall must be configured to allow outgoing port 514 for Syslog. Use the command esxcfgfirewall -o 514,udp,out,syslog to open port 514 and the command esxcfgfirewall -c 514,udp,out,syslog to block outgoing traffic through port 514. HP StorageWorks DC SAN Director support in Professional Plus DCFM Professional Plus edition can discover, but not manage, the HP DC SAN Backbone chassis. To manage the device, launch the device Element Manager from the Connectivity Map. The HP DC SAN Backbone Director cannot be used as a seed switch. Uninstalling ODBC DCFM install location With DCFM 10.0.x and later, when ODBC is installed in the DCFM install location, uninstalling ODBC will not remove the odbc folder from the DCFM location and the ODBC driver shortcut menu item will not be removed. HP recommends that you remove it manually. Configuring OBDC connection manually With DCFM 10.0.x and later, when the configuration page is skipped during ODBC installation, you can create DSN at a later time by accessing install home \odbc\createdsn.bat Failover restriction in mixed fabrics In mixed fabrics, the seed switch must be a Fabric OS switch. You cannot change the seed switch to EOS manually. In this situation, to manage the fabric with EOS as the seed switch: 1. Disconnect the ISL between the Fabric OS and EOS switches. 2. Unmonitor or delete the Fabric OS fabric. 3. Discover the Pure EOS Fabric by providing the EOS seed switch IP address. Failover (that is, when the seed switch is not reachable, falling back to another switch as seed switch) can occur in the following cases: • Fabric OS to Fabric OS switches • EOS to EOS switches • EOS to Fabric OS switches • Fabric OS to EOS switches FICON Emulation restrictions in FCIP Tunnel configuration The FICON Emulation tab in the FCIP Advanced Settings dialog allows (requires) configuration of FICON Debug Flags setting to configure any FICON settings. The recommended value for FICON 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Gateway is not displayed in the Topology. HP recommends that you disable F_Port trunking on the
switch before connecting it to the Access Gateway.
VMware firewall settings may require HCM agent to be restarted
If the firewall settings on port 514 changed in VMware, the HCM Agent must be restarted. VMware
(ESX 3.5 & 4) blocks the Syslog outgoing port 514 by default. If you are using a Syslog Host
configuration or HCM as part of DCFM, the firewall must be configured to allow outgoing port 514
for Syslog.
Use the command
esxcfgfirewall -o 514,udp,out,syslog
to open port 514 and the
command
esxcfgfirewall -c 514,udp,out,syslog
to block outgoing traffic through port
514.
HP StorageWorks DC SAN Director support in Professional Plus
DCFM Professional Plus edition can discover, but not manage, the HP DC SAN Backbone chassis.
To manage the device, launch the device Element Manager from the Connectivity Map.
The HP DC SAN Backbone Director cannot be used as a seed switch.
Uninstalling ODBC DCFM install location
With DCFM 10.0.x and later, when ODBC is installed in the DCFM install location, uninstalling ODBC
will not remove the
odbc
folder from the DCFM location and the ODBC driver shortcut menu item
will not be removed. HP recommends that you remove it manually.
Configuring OBDC connection manually
With DCFM 10.0.x and later, when the configuration page is skipped during ODBC installation, you
can create DSN at a later time by accessing install home
\odbc\createdsn.bat
Failover restriction in mixed fabrics
In mixed fabrics, the seed switch must be a Fabric OS switch. You cannot change the seed switch to
EOS manually.
In this situation, to manage the fabric with EOS as the seed switch:
1.
Disconnect the ISL between the Fabric OS and EOS switches.
2.
Unmonitor or delete the Fabric OS fabric.
3.
Discover the Pure EOS Fabric by providing the EOS seed switch IP address.
Failover (that is, when the seed switch is not reachable, falling back to another switch as seed switch)
can occur in the following cases:
Fabric OS to Fabric OS switches
EOS to EOS switches
EOS to Fabric OS switches
Fabric OS to EOS switches
FICON Emulation restrictions in FCIP Tunnel configuration
The FICON Emulation tab in the FCIP Advanced Settings dialog allows (requires) configuration of
FICON Debug Flags setting to configure any FICON settings. The recommended value for FICON
14