HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 50

generated from Non Default Virtual Switches., tree of DC04 SAN Director.

Page 50 highlights

Closed defect summary Solution Product Menu is empty/lost for mapped port Server and Storage devices. Fixed in DCFM 10.4.0. Local client and remote client launch takes 30 to 40 seconds in case if no fabrics are discovered in DCFM. Fixed in DCFM 10.4.0. Local Client hangs when the total port count is 10172 ports. Fixed in DCFM 10.4.0. Not able to receive email when filter is configured in User Management window. Fixed in DCFM 10.4.0. In a single switch fabric, user is not able to uncheck the Show Ports option in Right click menu for the switch. Fixed in DCFM 10.4.0. The Operation has Failed error message is given while trying to delete a circuit. Workaround prior to upgrade: Reboot the switch and try to delete the tunnel. Fixed in DCFM 10.4.0. Chassis based Call home Events like power supply failure events are generated from Non Default Virtual Switches. Fixed in DCFM 10.4.0. Node descriptors are missing for DC SAN Backbone Director and DC04 SAN Director when the F_Port has null node name. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Wait When activating a new zone config, DCFM shows the old zone config until the Zone collection completes. as active. Fixed in DCFM 10.4.0. No functionalities are able to be performed when Web Tools is launched from the fabric tree of Web Tools for any B model switch. Workaround prior to upgrade: Launch Web Tools from the web browser for DC04 SAN Director and then try launching switch view from the fabric tree of DC04 SAN Director. Fixed in DCFM 10.4.0. For the existing tunnel which does not have description, if we edit and add the description, Tunnel goes DOWN and does not come UP. Fixed in DCFM 10.4.0. When Host Name is changed from the Property dialog box or Device Workaround prior to upgrade: Tree, it is not getting updated unless Client is relaunched or HBA is re- Relaunch Client; Rediscover HBA. discovered. Fixed in DCFM 10.4.0. NPE is given when the user tries to launch EWS for M model switch from the fabric tree. Fixed in DCFM 10.4.0. An Error message is displayed stating CAL/XML request failed (error: % Error: Unsupported PFC policy for PGID 2) while creating a CEE Fixed in DCFM 10.4.0. map. Upgraded to 10.3.1 and customer zones that previously contained aliases now have WWNs. Fixed in DCFM 10.4.0. Port Names are not being cleared during activation of a Saved Configuration File. Fixed in DCFM 10.4.0. Call Home event content list the different contributors when generate call home from default virtual switch which have FID other then 128. Fixed in DCFM 10.4.0. 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Solution
Closed defect summary
Fixed in DCFM 10.4.0.
Product Menu is empty/lost for mapped port Server and Storage
devices.
Fixed in DCFM 10.4.0.
Local client and remote client launch takes 30 to 40 seconds in case
if no fabrics are discovered in DCFM.
Fixed in DCFM 10.4.0.
Local Client hangs when the total port count is 10172 ports.
Fixed in DCFM 10.4.0.
Not able to receive email when filter is configured in User Management
window.
Fixed in DCFM 10.4.0.
In a single switch fabric, user is not able to uncheck the Show Ports
option in Right click menu for the switch.
Workaround prior to upgrade:
Reboot
the switch and try to delete the tunnel.
Fixed in DCFM 10.4.0.
The Operation has Failed
error message is given while trying
to delete a circuit.
Fixed in DCFM 10.4.0.
Chassis based Call home Events like power supply failure events are
generated from Non Default Virtual Switches.
Fixed in DCFM 10.4.0.
Node descriptors are missing for DC SAN Backbone Director and
DC04 SAN Director when the F_Port has null node name.
Workaround prior to upgrade:
Wait
until the Zone collection completes.
Fixed in DCFM 10.4.0.
When activating a new zone config, DCFM shows the old zone config
as active.
Workaround prior to upgrade:
Launch
Web Tools from the web browser for
DC04 SAN Director and then try
launching switch view from the fabric
tree of DC04 SAN Director.
Fixed in DCFM 10.4.0.
No functionalities are able to be performed when Web Tools is
launched from the fabric tree of Web Tools for any B model switch.
Fixed in DCFM 10.4.0.
For the existing tunnel which does not have description, if we edit and
add the description, Tunnel goes DOWN and does not come UP.
Workaround prior to upgrade:
Relaunch Client; Rediscover HBA.
Fixed in DCFM 10.4.0.
When Host Name is changed from the Property dialog box or Device
Tree, it is not getting updated unless Client is relaunched or HBA is re-
discovered.
Fixed in DCFM 10.4.0.
NPE is given when the user tries to launch EWS for M model switch
from the fabric tree.
Fixed in DCFM 10.4.0.
An Error message is displayed stating CAL/XML request failed (error:
% Error: Unsupported PFC policy for PGID 2)  while creating a CEE
map.
Fixed in DCFM 10.4.0.
Upgraded to 10.3.1 and customer zones that previously contained
aliases now have WWNs.
Fixed in DCFM 10.4.0.
Port Names are not being cleared during activation of a Saved Con-
figuration File.
Fixed in DCFM 10.4.0.
Call Home event content list the different contributors when generate
call home from default virtual switch which have FID other then 128.
50