HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 40

VE_Port number in the Switch-2 side Tunnels TAB and the Circuit TAB

Page 40 highlights

Closed defect summary Solution In the FCIP Tunnel dialog box, newly created tunnel does not show the VE_Port number in the Switch-2 side Tunnels TAB and the Circuit TAB are not displaying the data properly. Workaround prior to upgrade: Click on any one tunnel [Either Switch-1 side or Switch-2 side]. Proper information will be shown in the Bottom panel. Fixed in DCFM 10.4.0. Workaround prior to upgrade: IFL is not shown between the fabrics when the user changes the VE-VE Un-monitor and monitor the fabrics. connection to VE-VEX between 400 multiprotocol routers. Fixed in DCFM 10.4.0. When different clients are logged in with same username but different Workaround prior to upgrade: Restart case, then creating, editing and copying views in one client do not the client to see the changes. dynamically update in the other client. Fixed in DCFM 10.4.0. Sorting function is not working in Available table in Port Picker dialog box of Realtime Graph, Historical Graph and Report. Fixed in DCFM 10.4.0. HAFM references should be removed from the available call home centers. Fixed in DCFM 10.4.0. After migrating from CM, Custom community string is copied to AG switch, when the connected McDATA switch was discovered with custom community string. Fixed in DCFM 10.4.0. While enabling the tunnel which is persistently disabled, alert has been given to the user but Enable Tunnel button gets disabled and Disable Fixed in DCFM 10.4.0. Tunnel button gets enabled. When the tunnel creation fails for the valid reason, if we rollback the changes, roll back was successful, but after some time, tunnel with EMPTY details is displayed in the FCIP Tunnel dialog box. Fixed in DCFM 10.4.0. Improve LIC error message when there is no fabric being managed by DCFM, current message causes confusion. Fixed in DCFM 10.4.0. Duplicate WWNs are accepted while launching Fabric_Switch_Configuration_Backup dialog box through LIC. Fixed in DCFM 10.4.0. Edit tunnel operation failed when trying to edit the tunnel present between 1606 extension SAN switch and multiprotocol extension blade. Fixed in DCFM 10.4.0. Configuring Scheduled backup when launched through remote client takes the time of the client instead of the server's time. Workaround prior to upgrade: Schedule backup based on client time only. Fixed in DCFM 10.4.0. In Fabric port report, Incorrect port count shown in Total Fabric Ports. Fixed in DCFM 10.4.0. RNID data for direct managed MEOS switches does not appear in the node descriptor list in DCFM. Fixed in DCFM 10.4.0. Some Events are not filtered out properly when filtering the master log events through Define Filter dialog box. Fixed in DCFM 10.4.0. 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Solution
Closed defect summary
Workaround prior to upgrade:
Click
on any one tunnel [Either Switch-1
side or Switch-2 side]. Proper
information will be shown in the
Bottom panel.
Fixed in DCFM 10.4.0.
In the FCIP Tunnel dialog box, newly created tunnel does not show the
VE_Port number in the Switch-2 side Tunnels TAB and the Circuit TAB
are not displaying the data properly.
Workaround prior to upgrade:
Un-monitor and monitor the fabrics.
Fixed in DCFM 10.4.0.
IFL is not shown between the fabrics when the user changes the VE-VE
connection to VE-VEX between 400 multiprotocol routers.
Workaround prior to upgrade:
Restart
the client to see the changes.
Fixed in DCFM 10.4.0.
When different clients are logged in with same username but different
case, then creating, editing and copying views in one client do not
dynamically update in the other client.
Fixed in DCFM 10.4.0.
Sorting function is not working in Available table in Port Picker dialog
box of Realtime Graph, Historical Graph and Report.
Fixed in DCFM 10.4.0.
HAFM references should be removed from the available call home
centers.
Fixed in DCFM 10.4.0.
After migrating from CM, Custom community string is copied to AG
switch, when the connected McDATA switch was discovered with
custom community string.
Fixed in DCFM 10.4.0.
While enabling the tunnel which is persistently disabled, alert has been
given to the user but Enable Tunnel button gets disabled and Disable
Tunnel button gets enabled.
Fixed in DCFM 10.4.0.
When the tunnel creation fails for the valid reason, if we rollback the
changes, roll back was successful, but after some time, tunnel with
EMPTY details is displayed in the FCIP Tunnel dialog box.
Fixed in DCFM 10.4.0.
Improve LIC error message when there is no fabric being managed
by DCFM, current message causes confusion.
Fixed in DCFM 10.4.0.
Duplicate WWNs are accepted while launching Fabric_Switch_Con-
figuration_Backup dialog box through LIC.
Fixed in DCFM 10.4.0.
Edit tunnel operation failed when trying to edit the tunnel present
between 1606 extension SAN switch and multiprotocol extension
blade.
Workaround prior to upgrade:
Schedule backup based on client time
only.
Fixed in DCFM 10.4.0.
Configuring Scheduled backup when launched through remote client
takes the time of the client instead of the server
s time.
Fixed in DCFM 10.4.0.
In Fabric port report, Incorrect port count shown in Total Fabric Ports.
Fixed in DCFM 10.4.0.
RNID data for direct managed MEOS switches does not appear in the
node descriptor list in DCFM.
Fixed in DCFM 10.4.0.
Some Events are not filtered out properly when filtering the master log
events through Define Filter dialog box.
40