HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 48
switch with CIM classes CIM_Collection, CIM_Product, CIM_ManagedEle
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Closed defect summary Solution AssociatorNames fails for Brocade_SanProtocolEndPoint for Phantom switch with CIM classes CIM_Collection,CIM_Product,CIM_ManagedEle- Fixed in DCFM 10.4.0. ment. Unable to change "Enabled Default" value of Brocade_SwitchFCPort. Fixed in DCFM 10.4.0. Switch Instances were not returned while traversing from other classes to switch in a mixed fabric, but able to get instances while traversing Fixed in DCFM 10.4.0. from switch to other classes. Association operations failed from the class Brocade_Node to Brocade_HBAFCPort with Exception CIMM_ERR_FAILED. Fixed in DCFM 10.4.0. Brocade_SANProtocolEndPoint instances are not associated to Brocade_LogicalNetwork. Fixed in DCFM 10.4.0. Application does not highlight all the items which are found, during a search, in the Switch Configuration Repository dialog box. Workaround prior to upgrade: Repeatedly click search button to reach the desired word. Fixed in DCFM 10.4.0. When DCFM is restored from a previous backup that is SSL enabled to a non-SSL (default) fresh install, user fails to login. Workaround prior to upgrade: Restart the server. Fixed in DCFM 10.4.0. Error message does not give sufficient information for the user when trying to activate more than 4096 unique members in IM2 and IM3. Fixed in DCFM 10.4.0. Device tree is collapsed automatically when the newly added column is edited in Linux. Fixed in DCFM 10.4.0. When Access Gateway is enabled in the switch extra HBA icon is displayed in Topology with AG WWN along with AG that is connected Fixed in DCFM 10.4.0. to the Fabric. Application should get updated with the latest information from the switch in a reasonable time when there is any SNMP configuration changes. Fixed in DCFM 10.4.0. Logs are shown inconsistently in the Master log' when the Filter conditions have been 'Applied or Removed' continuously in the Define Filter dialog box. Workaround prior to upgrade: Restart the client to see the correct logs. Fixed in DCFM 10.4.0. In Pure MEOS the Threshold (Link) assigned to fabric is not inherited when a new switch joins the fabric, Workaround prior to upgrade: Open the Port fencing dialog box and once again apply the same policy at the fabric; it will be applied to all the newly added switches. Fixed in DCFM 10.4.0. Trunk E_Port is shown as L port in Topology and shown connected to the Storage device. Workaround prior to upgrade: Start a new client after 30 minutes. Fixed in DCFM 10.4.0. 48