HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 35

Add FCIP Circuit dialog box

Page 35 highlights

Closed defect summary Solution Unable to create Single side tunnel when Uncommitted is checked in Add FCIP Circuit dialog box. Workaround prior to upgrade: Check the Committed option and able to create the tunnel Fixed in DCFM 10.4.0. Auto enclosure is not created in the Fabric view after discovering Host and wrong fabric WWN is shown in the Host view. Fixed in DCFM 10.4.0. Activating a configuration without loading to Right Hand Side (PDCM Matrix) fails and NPE is thrown in the Client. Workaround prior to upgrade: Load the configuration in the Right hand side and then activate the configuration. Fixed in DCFM 10.4.0. Fault Management : Master log event count is incremented with the old source name even when the switch name is changed. Fixed in DCFM 10.4.0. Seed Switch failover does not happen to Switch 3 in pure EOS fabric as DCFM does not release the NMRU link of Switch 2. Fixed in DCFM 10.4.0. An additional entry of WWN is being added in the zones table when a CNA is added to a Zone. Workaround prior to upgrade: By removing the Extra entry of WWN from the Zones table, user can activate the Zone configuration Fixed in DCFM 10.4.0. View Utilization menu item is disabled in Fabric view when the discovered Host is deleted Workaround prior to upgrade: Select any Fabric or Switch in the Device Tree Fixed in DCFM 10.4.0. Discovery dialog box is not showing the status "SNMP communication failed. SNMP credentials may be invalid" when the user fails to provide the configured Auth\ priv passwords in DCFM. Workaround prior to upgrade: Provide all the configured v3 credentials when discovering the switch. Fixed in DCFM 10.4.0. Delete of a logical switch failed, server errors about moving port from and to the same FID. Fixed in DCFM 10.4.0. When context name field is empty, SNMPv3 trap forwarding is failed. Workaround prior to upgrade: Fill any value in the context name field. - If the correct user name, Auth/Priv protocol and password are set, the trap will be forwarded to the destination. Fixed in DCFM 10.4.0. After migration from 10.1.x Enterprise Edition to 10.3.1 Enterprise Edition, Mi10k is not getting manageability in Mixed fabric if discovered through APIuser in DCFM 10.1.x Workaround prior to upgrade: To get manageability after migration, Go to SNMP tab for Mi10k switch in Edit dialog box and check the "Configure for Intrepid 10k" checkbox. Fixed in DCFM 10.4.0. B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Solution
Closed defect summary
Workaround prior to upgrade:
Check
the Committed option and able to
create the tunnel
Fixed in DCFM 10.4.0.
Unable to create Single side tunnel when Uncommitted is checked in
Add FCIP Circuit dialog box.
Fixed in DCFM 10.4.0.
Auto enclosure is not created in the Fabric view after discovering Host
and wrong fabric WWN is shown in the Host view.
Workaround prior to upgrade:
Load
the configuration in the Right hand
side and then activate the
configuration.
Fixed in DCFM 10.4.0.
Activating a configuration without loading to Right Hand Side (PDCM
Matrix) fails and NPE is thrown in the Client.
Fixed in DCFM 10.4.0.
Fault Management : Master log event count is incremented with the
old source name even when the switch name is changed.
Fixed in DCFM 10.4.0.
Seed Switch failover does not happen to Switch 3 in pure EOS fabric
as DCFM does not release the NMRU link of Switch 2.
Workaround prior to upgrade:
By
removing the Extra entry of WWN
from the Zones table, user can
activate the Zone configuration
Fixed in DCFM 10.4.0.
An additional entry of WWN is being added in the zones table when
a CNA is added to a Zone.
Workaround prior to upgrade:
Select
any Fabric or Switch in the Device
Tree
Fixed in DCFM 10.4.0.
View Utilization menu item is disabled in Fabric view when the dis-
covered Host is deleted
Workaround prior to upgrade:
Provide all the configured v3
credentials when discovering the
switch.
Fixed in DCFM 10.4.0.
Discovery dialog box is not showing the status
SNMP communication
failed. SNMP credentials may be invalid
when the user fails to provide
the configured Auth\ priv passwords in DCFM.
Fixed in DCFM 10.4.0.
Delete of a logical switch failed, server errors about moving port from
and to the same FID.
Workaround prior to upgrade:
Fill any
value in the context name field. - If the
correct user name, Auth/Priv protocol
and password are set, the trap will
be forwarded to the destination.
Fixed in DCFM 10.4.0.
When context name field is empty, SNMPv3 trap forwarding is failed.
Workaround prior to upgrade:
To get
manageability after migration, Go to
SNMP tab for Mi10k switch in Edit
dialog box and check the "Configure
for Intrepid 10k" checkbox.
Fixed in DCFM 10.4.0.
After migration from 10.1.x Enterprise Edition to 10.3.1 Enterprise
Edition, Mi10k is not getting manageability in Mixed fabric if dis-
covered through APIuser in DCFM 10.1.x
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional
35