HP 2000fc Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide - Page 128
show enclosure-status on set expander-fault-isolation
View all HP 2000fc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 128 highlights
Example Disable the first egress PHY in both controllers in an enclosure, after determining the PHY index; then verify the PHY's status. # show expander-status Encl Phy Type Status 0 0 DRIVE OK
128
HP StorageWorks 2000 Family Modular Smart Array CLI reference guide
•
May 2008
Example
Disable the first egress PHY in both controllers in an enclosure, after determining
the PHY index; then verify the PHY’s status.
Related Commands
■
“set expander-fault-isolation” on page 125
■
“show enclosure-status” on page 178
■
“show expander-status” on page 184
#
show expander-status
Encl Phy
Type
Status
-------------------------------------
0
0
DRIVE
OK
<= Index 0
0
1
DRIVE
OK
0
2
DRIVE
OK
0
3
DRIVE
OK
0
4
DRIVE
OK
0
5
DRIVE
OK
0
6
DRIVE
OK
0
7
DRIVE
OK
0
8
DRIVE
OK
0
9
DRIVE
OK
0
10
DRIVE
OK
0
11
DRIVE
OK
0
0
INTER-EXP
OK
<= Index 12
0
1
INTER-EXP
OK
0
2
INTER-EXP
OK
0
3
INTER-EXP
OK
0
0
SC
OK
0
1
SC
OK
0
2
SC
OK
0
3
SC
OK
0
0
EGRESS
Error
<= Index 20
...
#
set expander-phy wwn 500C0FF00A408A3C controller both index 20
disable
Success: Disabled Phy #20.
#
show expander-status
...
0
0
EGRESS
Disabled
...