HP 2000fc Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide - Page 131
controller A port 0., show host-port-interconnects
View all HP 2000fc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 131 highlights
Example For an FC storage system, set the link speed to 2 Gbit/sec for controller A port 1 and for controller B port 0. # set host-parameters controller a speed 2g channel 1 WARNING: You have requested a change on host channel parameters. This change will take effect immediately. If the link speed is changed, your current link may go down. If the topology is changed between 'loop' and 'point-to-point', you may not be able to use dual ID mode for failover and your ability to access LUNs from some hosts will be limited. Are you sure? yes For an FC storage system, set the topology of controller A host ports to loop. # set host-parameters controller a channel all fibre-connectionmode loop WARNING: You have requested a change on host channel parameters. This change will take effect immediately. If the link speed is changed, your current link may go down. If the topology is changed between 'loop' and 'point-to-point', you may not be able to use dual ID mode for failover and your ability to access LUNs from some hosts will be limited. Are you sure? yes For an iSCSI storage system, set the port IP address, netmask, and gateway for controller A port 0. # set host-parameters controller a channel 0 ip 192.168.0.10 netmask 255.255.255.0 gateway 192.168.0.1 Success: iSCSI host parameters changed successfully. Related Commands ■ "show host-parameters" on page 190 ■ "show host-port-interconnects" on page 193 Chapter 3 Command Descriptions 131