HP 600 HP StorageWorks 600 Modular Disk System Maintenance and Service Guide - Page 59
SAS and SATA hard drive LED combinations
View all HP 600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
SAS and SATA hard drive LED combinations Online/activity Fault/UID LED LED (green) (amber/blue) On, off, or flashing Alternating amber and blue On, off, or flashing Steadily blue On On Flashing regularly (1 Hz) Amber, flashing regularly (1 Hz) Off Amber, flashing regularly (1 Hz) Flashing regularly Off (1 Hz) Flashing irregularly Amber, flashing regularly (1 Hz) Flashing irregularly Off Off Steadily amber Off Amber, flashing regularly (1 Hz) Off Off Interpretation The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application. The drive is operating normally, and it has been selected by a management application. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is online, but it is not currently active. Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or a stripe size migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete. Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or a stripe size migration. The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is active and it is operating normally. A critical fault condition has been identified for this drive and the controller has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. Component identification 59