NOTE: When calculating the Power Limit Watts ac value, derate the circuit to 80% of the maximum to prevent tripping the circuit breaker (United States only). NOTE: If your facility cannot support the calculated peak Watts ac, set the Power Watts ac value to match the capability of your facility. • Dynamic Power -The default setting is Enabled. The following selections are valid: ◦ Enabled -Some of the power supplies can be automatically placed on standby to increase overall enclosure power subsystem efficiency. ◦ Disabled -All power supplies share the load; the power subsystem efficiency varies based on load. • OA1 IP Addr- The default setting is DHCP; if no IP address is received, the IP address is 0.0.0.0. The IP address, mask, and gateway are set within this option. • OA2 IP Addr- If this module is present, the default setting is DHCP; if no IP address is received, the IP address is 0.0.0.0. If only one Onboard Administrator module is installed, then the screen displays "Not Present". • Enclosure Name- The default setting is a unique factory-assigned name. The accepted character values are 0-9, A-Z ,a-z, -, _, and the box character. The box character is used to signal the end of the name. NOTE: Do not use the box character in the middle of a text box. Entries in text boxes are truncated to the last character before the box character. TIP: Select Clear from the navigation bar to quickly clear entries in text boxes up to the symbol. • Rack Name - The default setting is UnnamedRack. The accepted character values are 0-9, A-Z, a-z, -, _, and the box character. The box character is used to signal the end of the name. • DVD Drive- The DVD connection Settings screen is a table of all the servers with the status of DVD Connection and blade name for that blade. Running the Insight Display installation 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

NOTE:
When calculating the Power Limit Watts ac value, derate the circuit to 80% of
the maximum to prevent tripping the circuit breaker (United States only).
NOTE:
If your facility cannot support the calculated peak Watts ac, set the Power Watts
ac value to match the capability of your facility.
Dynamic Power
—The default setting is Enabled. The following selections are valid:
Enabled
—Some of the power supplies can be automatically placed on standby to
increase overall enclosure power subsystem efficiency.
Disabled
—All power supplies share the load; the power subsystem efficiency varies
based on load.
OA1 IP Addr
— The default setting is DHCP; if no IP address is received, the IP address
is 0.0.0.0. The IP address, mask, and gateway are set within this option.
OA2 IP Addr
— If this module is present, the default setting is DHCP; if no IP address is
received, the IP address is 0.0.0.0. If only one Onboard Administrator module is installed,
then the screen displays “Not Present”.
Enclosure Name
— The default setting is a unique factory-assigned name. The accepted
character values are 0-9, A-Z ,a-z, -, _, and the box character. The box character is used
to signal the end of the name.
NOTE:
Do not use the box character in the middle of a text box. Entries in text boxes
are truncated to the last character before the box character.
TIP:
Select
Clear
from the navigation bar to quickly clear entries in text boxes up to the
symbol.
Rack Name
— The default setting is UnnamedRack. The accepted character values are
0-9, A-Z, a-z, -, _, and the box character. The box character is used to signal the end of
the name.
DVD Drive
— The DVD connection Settings screen is a table of all the servers with the
status of DVD Connection and blade name for that blade.