HP Integrity Superdome 2 16-socket HP Integrity Superdome 2 User Service Guide - Page 63

IOX enclosure rear, I/O bay 1 PCIe slots

Page 63 highlights

IOX enclosure rear Item Name Description 1 Link Cable Status LEDs Indicates the status of the Xbar Fabric link. Solid green = Link OK, transmitting at full bandwidth Alternating green/yellow = Link in service, safe to remove. Flashing yellow = Deconfigured link, safe to remove. CAUTION: Always use the HR user interface stop link command before disconnecting the Superdome 2 crossbar fabric cable. The stop link command will allow safe servicing and set the LED endpoints for easy location. After servicing, the HR start link command will enable re-use of the link. 2 CAMNet port 1 See following table. 3 Power supply 1 LED indicates status: Green = OK Off = No ac or failed 4 Power supply 2 LED indicates status: Green = OK Off = No ac or failed 5 CAMNet port 2 See following table. 6 I/O bay 2 PCIe slots 7 I/O bay 1 PCIe slots Troubleshooting tools 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

IOX enclosure rear
Description
Name
Item
Indicates the status of the Xbar Fabric
link.
Link Cable Status LEDs
1
Solid green = Link OK, transmitting at
full bandwidth
Alternating green/yellow = Link in
service, safe to remove.
Flashing yellow = Deconfigured link,
safe to remove.
CAUTION:
Always use the HR user
interface
stop link
command before
disconnecting the Superdome 2
crossbar fabric cable. The
stop link
command will allow safe servicing and
set the LED endpoints for easy location.
After servicing, the HR
start link
command will enable re-use of the link.
See following table.
CAMNet port 1
2
LED indicates status:
Power supply 1
3
Green = OK
Off = No ac or failed
LED indicates status:
Power supply 2
4
Green = OK
Off = No ac or failed
See following table.
CAMNet port 2
5
I/O bay 2 PCIe slots
6
I/O bay 1 PCIe slots
7
Troubleshooting tools
63