HP StorageWorks 8/80 Brocade Fabric Watch Administrator's Guide v6.2.0 (53-100 - Page 72

Resource class default settings, TABLE 18

Page 72 highlights

7 Class default settings TABLE 17 Area F/FL_Port class default settings (Continued) Description Default threshold settings Default alarm settings Threshold state Loss of Signal Count Monitors the number Unit: Errors of signal loss errors Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range Link Reset Monitors the number Unit: Errors of link resets sent by Time Base: minute a given port (LR-Out) Low: 0 and received on a High: 500 given port (LR-In). Buffer: 50 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range Primitive Sequence Protocol Error Monitors the number Unit: Errors of primitive sequence Time Base: minute errors Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range Resource class default settings Table 18 provides default settings for areas in the Resource class. TABLE 18 Resource class default settings Area Description Default threshold settings Default alarm settings Threshold state Flash Monitors the Unit: Percentage (%) percentage of compact Time base: none flash used Low: 0 High: 85 Buffer: 0 Changed: 0 Below: 3 Above: 3 In-Between: 1 Informative Informative Out_of_range In_range 50 Fabric Watch Administrator's Guide 53-1001188-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

50
Fabric Watch Administrator’s Guide
53-1001188-01
Class default settings
7
Resource class default settings
Table 18
provides default settings for areas in the Resource class.
Loss of Signal Count
Monitors the number
of signal loss errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Reset
Monitors the number
of link resets sent by
a given port (LR-Out)
and received on a
given port (LR-In).
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Primitive Sequence
Protocol Error
Monitors the number
of primitive sequence
errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
TABLE 18
Resource class default settings
Area
Description
Default threshold settings
Default alarm settings
Threshold state
Flash
Monitors the
percentage of compact
flash used
Unit: Percentage (%)
Time base: none
Low: 0
High: 85
Buffer: 0
Changed: 0
Below: 3
Above: 3
In-Between: 1
Informative
Informative
Out_of_range
In_range
TABLE 17
F/FL_Port class default settings (Continued)
Area
Description
Default threshold
settings
Default alarm settings
Threshold state