HP StorageWorks 8/80 Brocade Fabric Watch Administrator's Guide v6.2.0 (53-100 - Page 76
SFP class default settings, TABLE 20
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
7 Class default settings SFP class default settings Table 20 provides default settings for areas in the SFP class. NOTE SFPs connected to GbE ports are not monitored. TABLE 20 Area SFP class default settings Description Default threshold settings Current Receive Power Supply Voltage Monitors SFP current Unit: mA Time Base: none Low: 0 High: 50 Buffer: 1 Monitors receive power Unit: µWatts in µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Monitors SFP electrical Unit: mV force in volts Time Base: none Low: 3150 High: 3600 Buffer: 10 Temperature Monitors SFP Temperature Transmit Power Monitors transmit power in µWatts Unit: Degrees C Time Base: none Low: -10 High: 85 Buffer: 3 Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Default alarm settings Threshold state Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 1 Informative Out_of_range Out_of_range Normal Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Normal 54 Fabric Watch Administrator's Guide 53-1001188-01