Disable FCR routing and Ex_Ports and, ageWorks DC SAN Backbone Director in fabric.
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
After hareboot, Probing failed on F_Port messages may be seen on the HP StorageWorks 8/8, 8/24, 8/40, and 8/80 SAN Fixed in Fabric OS 6.2.0. switches. HP 400 MP Router panicked after TI zone activation. Fixed in Fabric OS 6.2.0. B-series Multi-protocol Router blade faulted after overnight stress testing. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Do not configure an FCIP Tunnel. Received error message with high temperature (89) on edge HP StorageWorks DC SAN Backbone Director in fabric. Fixed in Fabric OS 6.2.0. The portcfgnpivport CLI command will not toggle trunked slave ports if the user disables NPIV configuration on that port. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: The user must manually toggle (enable/disable) the slave port to complete the operation. Faulted (51) core blade due to POST failure, resulted from overnight power cycle test. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Disable the diagnostic POST, then slotpoweroff on the faulted core blade. After attempting cfgdisable on a system in native interopmode and with default zoning set to all access and a large zoneset of at least Fixed in Fabric OS 6.2.0. 460 devices, the switch became faulty. No F_RJT's being returned for class 2 frames that are not routable according to a QoS/TI configuration. Fixed in Fabric OS 6.2.0. B-series Multi-protocol Router blade failed to do blade firmwaredownload. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Perform slot power off / slot power on the blade that timed out. Switch reboots when IFL is enabled. Fixed in Fabric OS 6.2.0. Frame drop observed after creating a TI zone with failover enabled in the backbone fabric ( TI over FCR). Fixed in Fabric OS 6.2.0. Hard Zoning disabled when ports toggle. Fixed in Fabric OS 6.2.0. Pathinfo doesn't match urouteshow and rtedebug. Fixed in Fabric OS 6.2.0. Sensors show incorrect command output in fully loaded HP StorageWorks DC SAN Backbone Director. Fixed in Fabric OS 6.2.0. Update to VC assignment scheme within core ASIC management structure. Fixed in Fabric OS 6.2.0. Fast Write performance issue with a particular FCIP Ex_Port configuration. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Disable FCR routing and Ex_Ports and merge the fabric into one large fabric. 38