HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355 - Page 48
Fabric OS 6.2.0d fixes
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Fabric OS 6.2.0d fixes The following table lists defects closed in the Fabric OS 6.2.0d firmware release. Table 12 Fabric OS 6.2.0d closed defects Closed defect summary Solution Brocade 8-Gb SAN Switch for HP BladeSystem c-Class requires up- Updated serdes values are provided dated serdes values for proper operation with 8-Gb mezzanine HBAs. in Fabric OS 6.2.0d. An out-of-memory condition can occur, leading to a switch panic due Fixed in Fabric OS 6.2.0d to memory leak when an E_Port constantly goes on and off. An out-of-memory condition can occur during hafailover/hareboot, leading to a switch panic due to memory leak when querying connUnitPortFCId in Access Gateway mode, as well as when querying FcFeModuleName. Workaround prior to upgrade: Avoid querying FcFeModuleName or connUnitPortFCId in AG mode. Fixed in Fabric OS 6.2.0d On rare occasions, HP StorageWorks DC SAN Director may panic in Fixed in Fabric OS 6.2.0d RTE module and hafailover during supportsave. During HA recovery, Fabric Watch reports switch health as marginal/down on fully populated HP StorageWorks DC SAN Director. Traffic Fixed in Fabric OS 6.2.0d is not impacted, but DCFM call home will not be initiated. After HAfailover, SNMP v3 user configuration reverts back to default values when configuring SNMP v3 user configuration on any one of Fixed in Fabric OS 6.2.0d the user-defined USM configuration sets. Detected termination of 0.weblinker.fcg on HP StorageWorks DC04 SAN Director and messages like KSWD-1002, 5766, SLOT Fixed in Fabric OS 6.2.0d 4 | FFDC | CHASSIS, WARNING displayed on the console. After enabling Virtual Fabric via DCFM on HP StorageWorks 8/40 SAN Switch, some ports may be disabled. Fixed in Fabric OS 6.2.0d Missing FICON interrupt on HP StorageWorks DC04 SAN Director due to CUP not responding in time before channel timed out. Fixed in Fabric OS 6.2.0d Security commands such as fddcfg -fabwideset fail with RCS transaction error. Fixed in Fabric OS 6.2.0d When performing firmwareupgrade from Fabric OS 6.1x to 6.2.0 then reverting back to 6.1.x via firmwarerestore, the downgrade fails and leaves the CP with unrecoverable passwords, leaving it in an inconsistent state where the user may not be able to login. Workaround prior to upgrade: Once passwords are blocked, boot into single user mode and reset system passwords. Fixed in Fabric OS 6.2.0d Disconnecting/reconnecting an ISL on the HP StorageWorks Encryption SAN Switch while a rekey operation is in progress may result in failure Fixed in Fabric OS 6.2.0d of new key creation. LUN state shows Rekey ACK timeout. 48