HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355 - Page 51

Fabric OS 6.2.0f fixes

Page 51 highlights

Node descriptors missing from FICON RNID data for HP StorageWorks Fixed in Fabric OS 6.2.0e DC SAN Director and HP StorageWorks DC04 Director. Tape pipelining code randomly sends only data frames in an exchange Fixed in Fabric OS 6.2.0e to a tape drive over an FCIP link, leading to tape job failure. Portswap does not work for ports 32 - 47 on 48 port blade via the GUI for FICON. Fixed in Fabric OS 6.2.0e Registered Link Incident Records (RLIR) with Loss of Light (LOL) are being generated on 8 Gb channels during CEC Initial Machine Load (IML) Fixed in Fabric OS 6.2.0e in FICON environment. Tape pipelining code does not close exchange upon an ELS RJT response to REC -- invalid oxid/rxid combo causing write sequence failures. Tape reads are unaffected. Fixed in Fabric OS 6.2.0e Fibre Channel FastWrite (FCFW) corrupts buffer pool upon Turbo Write Fixed in Fabric OS 6.2.0e Block (TWB) allocation failure on Proxy Initiator leading to I/O failure. With HP StorageWorks DC SAN Director, Web Tools shows high host CPU usage (approximately 80%) when port configuration operation is performed on a large system. CPU usage goes back to normal once operation completes. Fixed in Fabric OS 6.2.0e Supportsave may show parity errors on disabled ports on a switch that has been upgraded from a lower code level to Fabric OS 6.1.2 and never cold booted. No errors will be caused on enabled ports, or after a disabled port is enabled. Fixed in Fabric OS 6.2.0e When a blade is hot plugged into an HP StorageWorks DC SAN Director or HP StorageWorks DC04 Director, its information will not appear in the embedded GUI. Fixed in Fabric OS 6.2.0e Lossless DLS failed with dropped frame causing IFCC in presence of Fixed in Fabric OS 6.2.0e ICLs. Fabric OS 6.2.0f fixes The following table lists defects closed in the Fabric OS 6.2.0f firmware release. Table 14 Fabric OS 6.2.0f closed defects Closed defect summary Solution Unexpected termination of a Remote Procedure Call (RPC) daemon occurs and then restarts non-disruptively. Fixed in Fabric OS 6.2.0f UNIX-based host with Fibre Channel FastWrite (FCFW) enabled hangs after a port disable/enable of HBA ports during a 400 MP Router re- Fixed in Fabric OS 6.2.0f boot. Executing configdownload via DCFM may cause a switch authentication failure for clients using the HTTP service. Workaround prior to upgrade: Execute hafailover or hareboot. Fixed in Fabric OS 6.2.0f HP StorageWorks Fabric OS 6.2.0g release notes 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Fixed in Fabric OS 6.2.0e
Node descriptors missing from FICON RNID data for HP StorageWorks
DC SAN Director and HP StorageWorks DC04 Director.
Fixed in Fabric OS 6.2.0e
Tape pipelining code randomly sends only data frames in an exchange
to a tape drive over an FCIP link, leading to tape job failure.
Fixed in Fabric OS 6.2.0e
Portswap does not work for ports 32 - 47 on 48 port blade via the
GUI for FICON.
Fixed in Fabric OS 6.2.0e
Registered Link Incident Records (RLIR) with Loss of Light (LOL) are being
generated on 8 Gb channels during CEC Initial Machine Load (IML)
in FICON environment.
Fixed in Fabric OS 6.2.0e
Tape pipelining code does not close exchange upon an ELS RJT re-
sponse to REC --
invalid oxid/rxid combo
causing write se-
quence failures. Tape reads are unaffected.
Fixed in Fabric OS 6.2.0e
Fibre Channel FastWrite (FCFW) corrupts buffer pool upon Turbo Write
Block (TWB) allocation failure on Proxy Initiator leading to I/O failure.
Fixed in Fabric OS 6.2.0e
With HP StorageWorks DC SAN Director, Web Tools shows high host
CPU usage (approximately 80%) when port configuration operation
is performed on a large system. CPU usage goes back to normal once
operation completes.
Fixed in Fabric OS 6.2.0e
Supportsave
may show parity errors on disabled ports on a switch
that has been upgraded from a lower code level to Fabric OS 6.1.2
and never cold booted. No errors will be caused on enabled ports,
or after a disabled port is enabled.
Fixed in Fabric OS 6.2.0e
When a blade is hot plugged into an HP StorageWorks DC SAN
Director or HP StorageWorks DC04 Director, its information will not
appear in the embedded GUI.
Fixed in Fabric OS 6.2.0e
Lossless DLS failed with dropped frame causing IFCC in presence of
ICLs.
Fabric OS 6.2.0f fixes
The following table lists defects closed in the Fabric OS 6.2.0f firmware release.
Table 14 Fabric OS 6.2.0f closed defects
Solution
Closed defect summary
Fixed in Fabric OS 6.2.0f
Unexpected termination of a Remote Procedure Call (RPC) daemon
occurs and then restarts non-disruptively.
Fixed in Fabric OS 6.2.0f
UNIX-based host with Fibre Channel FastWrite (FCFW) enabled hangs
after a port disable/enable of HBA ports during a 400 MP Router re-
boot.
Workaround prior to upgrade:
Execute
hafailover
or
hareboot
.
Fixed in Fabric OS 6.2.0f
Executing
configdownload
via DCFM may cause a switch authen-
tication failure for clients using the HTTP service.
HP StorageWorks Fabric OS 6.2.0g release notes