HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355 - Page 40

When an HP StorageWorks DC SAN Backbone Director blade is, On an HP StorageWorks 8/80 SAN Switch - storageworks 11 8 80

Page 40 highlights

Hareboot on 400 MP Router FC Fast Write enabled switch causes the system to panic with Oops: kernel access of bad area, Fixed in Fabric OS 6.2.0. sig: 11 [#1]. Fabric Mode TT displays redundant flows with different values for the same SID/DID pair on the core switches when there are redundant trunk groups to the same edge domain. Fixed in Fabric OS 6.2.0. DLS ON does not rebalance when ISLs to a different switch are removed on HP StorageWorks DC SAN Backbone Director and HP StorageWorks 8/80 SAN Switch. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Perform switchdisable and switchenable to force a rebalance of the routes. On an HP StorageWorks 8/80 SAN Switch, the system status LED does not flash amber/green when a power supply is faulted. Fixed in Fabric OS 6.2.0. User with admin role in some AD is able to add another user with admin role in AD as ALL. Fixed in Fabric OS 6.2.0. Reset to default button is grayed out always in SCSI vs. IP traffic setup window. Fixed in Fabric OS 6.2.0. USB Admin is not in sync with CLI when launched . It shows the correct info only when we click refresh button. Fixed in Fabric OS 6.2.0. Name Server database is being set with incorrect WWN's for NPIV nodes when port ALPA = 0x13. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Port ALPA must be set to default value of 0x00 for ports hosting NPIV nodes. Potential timeouts and aborts during Device Discovery and CU busy processing when using FICON XRC Emulation. Fixed in Fabric OS 6.2.0. When an HP StorageWorks DC SAN Backbone Director blade is powered off, Fabric Watch displays unnecessary warning message about SFP voltages. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Ignore messages; they indicate no problem and have no side effect. The EnumerateSelectedInstances CAL call returns a port that is not present in GFABRIC MS call. Fixed in Fabric OS 6.2.0. FICON Tape Write Pipelining does not function with converter. Fixed in Fabric OS 6.2.0. In configure tab under switch admin tab, if value entered in R_A_TOV and E_D_TOV is more than the threshold, the error message displays Fixed in Fabric OS 6.2.0. the wrong range of values to be entered. Integrated Routing with multiple ports in an EX_Port trunk, may not properly send an entire exchange on the same link. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Disable trunking on HP StorageWorks DC SAN Backbone Director and HP StorageWorks 8/8, 8/24, 8/40, and 8/80 SAN switches EX_Ports. Sort does not work on Accessible Devices screen of name server. Fixed in Fabric OS 6.2.0. 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Fixed in Fabric OS 6.2.0.
Hareboot
on 400 MP Router FC Fast Write enabled switch causes
the system to panic with
Oops: kernel access of bad area,
sig: 11 [#1]
.
Fixed in Fabric OS 6.2.0.
Fabric Mode TT displays redundant flows with different values for the
same SID/DID pair on the core switches when there are redundant
trunk groups to the same edge domain.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Perform
switchdisable
and
switchenable
to force a rebalance
of the routes.
DLS ON does not rebalance when ISLs to a different switch are re-
moved on HP StorageWorks DC SAN Backbone Director and HP
StorageWorks 8/80 SAN Switch.
Fixed in Fabric OS 6.2.0.
On an HP StorageWorks 8/80 SAN Switch, the system status LED
does not flash amber/green when a power supply is faulted.
Fixed in Fabric OS 6.2.0.
User with admin role in some AD is able to add another user with
admin role in AD as ALL.
Fixed in Fabric OS 6.2.0.
Reset to default
button is grayed out always in SCSI vs. IP traffic setup
window.
Fixed in Fabric OS 6.2.0.
USB Admin is not in sync with CLI when launched . It shows the correct
info only when we click refresh button.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Port ALPA must be set to default value
of 0x00 for ports hosting NPIV nodes.
Name Server database is being set with incorrect WWN's for NPIV
nodes when port ALPA = 0x13.
Fixed in Fabric OS 6.2.0.
Potential timeouts and aborts during Device Discovery and CU busy
processing when using FICON XRC Emulation.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Ignore messages; they indicate no
problem and have no side effect.
When an HP StorageWorks DC SAN Backbone Director blade is
powered off, Fabric Watch displays unnecessary warning message
about SFP voltages.
Fixed in Fabric OS 6.2.0.
The
EnumerateSelectedInstances CAL
call returns a port that
is not present in GFABRIC MS call.
Fixed in Fabric OS 6.2.0.
FICON Tape Write Pipelining does not function with converter.
Fixed in Fabric OS 6.2.0.
In configure tab under switch admin tab, if value entered in R_A_TOV
and E_D_TOV is more than the threshold, the error message displays
the wrong range of values to be entered.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable trunking on HP StorageWorks
DC SAN Backbone Director and HP
StorageWorks 8/8, 8/24, 8/40,
and 8/80 SAN switches EX_Ports.
Integrated Routing with multiple ports in an EX_Port trunk, may not
properly send an entire exchange on the same link.
Fixed in Fabric OS 6.2.0.
Sort does not work on Accessible Devices screen of name server.
40