HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2.0g release notes (5697-0355 - Page 42

Out of Order frames delivered to HP StorageWorks DC SAN Backbone

Page 42 highlights

XRC Emulation allows FICON Disk Control Unit paths to be activated with DPR Mode. Fixed in Fabric OS 6.2.0. FMS stuck busy condition caused host *MASTER* START PENDING upon bringing switch online to mainframe operating system. Fixed in Fabric OS 6.2.0. CP card of HP StorageWorks 4/256 SAN Director is set to FAULTY (51). Fixed in Fabric OS 6.2.0. HP StorageWorks 8/8, 8/24, 8/40, and 8/80 SAN switches: when normal fan activity is interrupted, the high RPM fan rate cycle time Fixed in Fabric OS 6.2.0. takes 1 hour. RLS request from FICON host receives LS_RJT 031F in Interopmode 2. Fixed in Fabric OS 6.2.0. FMS Mode enable failed due to insufficient frame filtering resources on some ports. Fixed in Fabric OS 6.2.0. HP StorageWorks DC SAN Backbone Director blades fault after resetting a server with 32 HBAs. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Power cycle the slot. Set port speed to anything other than autonegotiate. Fast Write configuration not properly installed after repeated, back-toback cable pull and re-inserts. Fixed in Fabric OS 6.2.0. Out of Order frames delivered to HP StorageWorks DC SAN Backbone Director via FICON channel from HP StorageWorks 8/40 SAN Switch Fixed in Fabric OS 6.2.0. attached to a storage device (DASD). CAL exception "Non-Secure tunnel can not be configured on the same port as IP sec enabled tunnels." come when trying to configure an IP Fixed in Fabric OS 6.2.0. Sec tunnel on a switch which already had Non secure tunnels in it. Fast Write will attempt to configure, even on an HP StorageWorks Bseries Multi-protocol Router blade that has failed to initialize successfully. Fixed in Fabric OS 6.2.0. Zoned crashes after HP StorageWorks DC SAN Backbone Director power cycle and zone transaction aborted Fixed in Fabric OS 6.2.0. SMIA does not have information about SFP/GBIC type for a port. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: The embedded platforms have well known user/server ports documented in the user manuals. The tag field of the node identifier command returned contains the port number on which the command was received, instead of the tag field Fixed in Fabric OS 6.2.0. of the device on the other end of the link. Gzoneinfo.htm is returning empty zone information on fabric with Fabric OS 6.1.1. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Reboot the switch. Kernel Panic on 8Gb SAN Switch for HP BladeSystem c-Class after firmwaredownload. Fixed in Fabric OS 6.2.0. 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Fixed in Fabric OS 6.2.0.
XRC Emulation allows FICON Disk Control Unit paths to be activated
with DPR Mode.
Fixed in Fabric OS 6.2.0.
FMS stuck busy condition caused host *MASTER* START PENDING
upon bringing switch online to mainframe operating system.
Fixed in Fabric OS 6.2.0.
CP card of HP StorageWorks 4/256 SAN Director is set to FAULTY
(51).
Fixed in Fabric OS 6.2.0.
HP StorageWorks 8/8, 8/24, 8/40, and 8/80 SAN switches: when
normal fan activity is interrupted, the high RPM fan rate cycle time
takes 1 hour.
Fixed in Fabric OS 6.2.0.
RLS request from FICON host receives LS_RJT 031F in Interopmode 2.
Fixed in Fabric OS 6.2.0.
FMS Mode enable failed due to insufficient frame filtering resources
on some ports.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Power cycle the slot. Set port speed
to anything other than autonegotiate.
HP StorageWorks DC SAN Backbone Director blades fault after reset-
ting a server with 32 HBAs.
Fixed in Fabric OS 6.2.0.
Fast Write configuration not properly installed after repeated, back-to-
back cable pull and re-inserts.
Fixed in Fabric OS 6.2.0.
Out of Order frames delivered to HP StorageWorks DC SAN Backbone
Director via FICON channel from HP StorageWorks 8/40 SAN Switch
attached to a storage device (DASD).
Fixed in Fabric OS 6.2.0.
CAL exception
Non-Secure tunnel can not be configured on the same
port as IP sec enabled tunnels.
come when trying to configure an IP
Sec tunnel on a switch which already had Non secure tunnels in it.
Fixed in Fabric OS 6.2.0.
Fast Write will attempt to configure, even on an HP StorageWorks B-
series Multi-protocol Router blade that has failed to initialize success-
fully.
Fixed in Fabric OS 6.2.0.
Zoned crashes after HP StorageWorks DC SAN Backbone Director
power cycle and zone transaction aborted
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
The embedded platforms have well
known user/server ports documented
in the user manuals.
SMIA does not have information about SFP/GBIC type for a port.
Fixed in Fabric OS 6.2.0.
The tag field of the node identifier command returned contains the port
number on which the command was received, instead of the tag field
of the device on the other end of the link.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch.
Gzoneinfo.htm
is returning empty zone information on fabric with
Fabric OS 6.1.1.
Fixed in Fabric OS 6.2.0.
Kernel Panic on 8Gb SAN Switch for HP BladeSystem c-Class after
firmwaredownload
.