IBM 43635gu Installation Guide - Page 45

Completing, installation

Page 45 highlights

ServeRAID-8s single-drop cable 7. Replace the front system fan assembly. a. Insert the fan assembly retaining tab over the right edge of the hard disk drive backplane; then, rotate the fan assembly toward the backplane. Do not fully close the fan assembly. b. Route the single-drop signal cable through one of the slots on the edge of the fan assembly; then, route the hard disk drive power drop cable through the other slot on the edge of the fan assembly. Ensure that the cables will not be pinched between the fan assembly and the hard disk drive backplane when the fan assembly is installed. c. Rotate the fan assembly toward the backplane until the release tabs are fully engaged. d. Rotate the drive cage back into the server until it stops; then, press and hold the retaining tab on top of the drive cage while rotating the drive cage into the chassis until it locks into place. 8. Reconnect the fan assembly cable to the system board. Note: Before you continue, check all internal power cables to make sure that they are connected to the system board and other optional devices. 9. Install the side cover (see "Reinstalling the side cover" on page 34). 10. Lock the side cover. 11. Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server. Completing the installation To complete the installation, you must reinstall the two-piece bezel, reinstall the side cover, connect all the cables and, for some devices, run the Configuration/Setup Utility program. Follow the instructions in this section. Chapter 2. Installing optional devices 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

ServeRAID-8s
single-drop cable
7.
Replace
the
front
system
fan
assembly.
a.
Insert
the
fan
assembly
retaining
tab
over
the
right
edge
of
the
hard
disk
drive
backplane;
then,
rotate
the
fan
assembly
toward
the
backplane.
Do
not
fully
close
the
fan
assembly.
b.
Route
the
single-drop
signal
cable
through
one
of
the
slots
on
the
edge
of
the
fan
assembly;
then,
route
the
hard
disk
drive
power
drop
cable
through
the
other
slot
on
the
edge
of
the
fan
assembly.
Ensure
that
the
cables
will
not
be
pinched
between
the
fan
assembly
and
the
hard
disk
drive
backplane
when
the
fan
assembly
is
installed.
c.
Rotate
the
fan
assembly
toward
the
backplane
until
the
release
tabs
are
fully
engaged.
d.
Rotate
the
drive
cage
back
into
the
server
until
it
stops;
then,
press
and
hold
the
retaining
tab
on
top
of
the
drive
cage
while
rotating
the
drive
cage
into
the
chassis
until
it
locks
into
place.
8.
Reconnect
the
fan
assembly
cable
to
the
system
board.
Note:
Before
you
continue,
check
all
internal
power
cables
to
make
sure
that
they
are
connected
to
the
system
board
and
other
optional
devices.
9.
Install
the
side
cover
(see
“Reinstalling
the
side
cover”
on
page
34).
10.
Lock
the
side
cover.
11.
Reconnect
the
external
cables
and
power
cords;
then,
turn
on
the
attached
devices
and
turn
on
the
server.
Completing
the
installation
To
complete
the
installation,
you
must
reinstall
the
two-piece
bezel,
reinstall
the
side
cover,
connect
all
the
cables
and,
for
some
devices,
run
the
Configuration/Setup
Utility
program.
Follow
the
instructions
in
this
section.
Chapter
2.
Installing
optional
devices
31